← Oklahoma

Tap water quality report

Lawton, OK

EPA monitoring detected 25 contaminants across the 11 water suppliers serving Lawton. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

11
water suppliers
99,224
people served
25
contaminants found

What was found in Lawton's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate-Nitrite
719 µg/L 7.2%
of the EPA limit 10000 µg/L
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 9276 µg/L — COMANCHE CO RWD #3 · 2,325 people · 2019
2/11 SYR4
Copper
357.9 µg/L 28%
of the EPA limit 1300 µg/L
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 934.4 µg/L — MOUNTAIN VILLAGE DEVELOPMENT · 77 people · 2018
11/11 SYR4
Fluoride
681 µg/L 17%
of the EPA limit 4000 µg/L
Main supplier: LAWTON · 92,757 people · 2019
3/11 SYR4
Nitrate
620 µg/L 6.2%
of the EPA limit 10000 µg/L
Main supplier: LAWTON · 92,757 people · 2015
1/11 SYR4
Barium
191.2 µg/L 9.6%
of the EPA limit 2000 µg/L
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 434.4 µg/L — COMANCHE CO RWD #3 · 2,325 people · 2017
3/11 SYR4
Chlorite
183.7 µg/L 18%
of the EPA limit 1000 µg/L
Main supplier: LAWTON · 92,757 people · 2019
1/11 SYR4
TTHM
28.805 µg/L 36%
of the EPA limit 80 µg/L
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 61.42 µg/L — MOUNTAIN VILLAGE DEVELOPMENT · 77 people · 2019
11/11 SYR4
Bromate
42.97 µg/L 430%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
Main supplier: LAWTON · 92,757 people · 2019
1/11 SYR4
Lead
29.45 µg/L 196%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: LAWTON · 92,757 people · 2019
9/11 SYR4
Total Haloacetic Acids (HAA5)
8.708 µg/L 15%
of the EPA limit 60 µg/L
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 23.625 µg/L — SOUTHEAST WATER ASSOCIATION · 51 people · 2019
11/11 SYR4
Dibromochloromethane
11.4 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 22.074 µg/L — MOUNTAIN VILLAGE DEVELOPMENT · 77 people · 2019
11/11 SYR4
Bromodichloromethane
8.394 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 20.95 µg/L — MOUNTAIN VILLAGE DEVELOPMENT · 77 people · 2019
11/11 SYR4
Chloroform
6.532 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 16.98 µg/L — SUNNYSIDE WATER ASSOC · 50 people · 2018
10/11 SYR4
Bromoform
12.1 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
11/11 SYR4
Chromium
9.7 µg/L 9.7%
of the EPA limit 100 µg/L
Highest in the city: COMANCHE CO RWD #3 · 2,325 people · 2017
1/11 SYR4
Dichloroacetic Acid
6.302 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 8.68 µg/L — CLEMMER WATER ASSOCIATION · 47 people · 2019
10/11 SYR4
Dibromoacetic Acid
5.4395 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 6.3635 µg/L — SUNNYSIDE WATER ASSOC · 50 people · 2018
10/11 SYR4
Trichloroacetic Acid
1.66 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 5.738 µg/L — MOUNTAIN VILLAGE DEVELOPMENT · 77 people · 2019
3/11 SYR4
Monobromoacetic Acid
1.6585 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 4.9 µg/L — CLEMMER WATER ASSOCIATION · 47 people · 2019
2/11 SYR4
Monochloroacetic Acid
3.49 µg/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2019
Highest in the city: 4.9 µg/L — CLEMMER WATER ASSOCIATION · 47 people · 2019
2/11 SYR4
Gross Alpha, Excl. Radon And U
1.7 pCi/L 11%
of the EPA limit 15 pCi/L
Main supplier: LAWTON · 92,757 people · 2015
Highest in the city: 4.781 pCi/L — COMANCHE CO RWD #3 · 2,325 people · 2017
3/11 SYR4
Gross Beta Particle Activity
3.54 pCi/L
No EPA limit set
Main supplier: LAWTON · 92,757 people · 2015
2/11 SYR4
Combined Radium (-226 And -228)
0.0935 pCi/L 1.9%
of the EPA limit 5 pCi/L
Main supplier: LAWTON · 92,757 people · 2015
Highest in the city: 2.7075 pCi/L — MOUNTAIN VILLAGE DEVELOPMENT · 77 people · 2018
2/11 SYR4
Combined Uranium
1.854 µg/L 6.2%
of the EPA limit 30 µg/L
Highest in the city: COMANCHE CO RWD #3 · 2,325 people · 2017
2/11 SYR4
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
Main supplier: LAWTON · 92,757 people · 2025
Highest in the city: 0.0041 mg/L — PECAN VALLEY RWD · 1,000 people · 2025
11/11 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Lawton

Frequently asked questions about Lawton tap water

Is Lawton tap water safe to drink?

EPA testing detected 25 contaminants in the water serving Lawton. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Lawton?

11 public water suppliers report drinking-water monitoring for Lawton, Oklahoma to the EPA. Each is listed above with its population served.

What contaminants are in Lawton's water?

The contaminants EPA monitoring detected in Lawton include Nitrate-Nitrite, Copper, Fluoride, Nitrate, Barium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.