← West Monroe, LA

Tap water quality report

ZIP 71225 — West Monroe, LA

EPA monitoring across the 2 water suppliers serving ZIP 71225 in West Monroe, LA detected 26 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

2
water suppliers
17,499
people served
26
contaminants found

What was found in ZIP 71225

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
292 µg/L 7.3%
of the EPA limit 4000 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
Highest in the ZIP: 482.5 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2017
2/2 SYR4
Copper
300 µg/L 23%
of the EPA limit 1300 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
Highest in the ZIP: 470 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
TTHM
95.01 µg/L 119%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 171.86 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Nitrate-Nitrite
96 µg/L 1%
of the EPA limit 10000 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 99 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Total Haloacetic Acids (HAA5)
22.605 µg/L 38%
of the EPA limit 60 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 71.4 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Bromodichloromethane
12.34 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 60.04 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Bromoform
55.21 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
2/2 SYR4
Chloroform
24.015 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 52.67 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Dibromochloromethane
37.25 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 52.14 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Monobromoacetic Acid
1.0725 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 33.205 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Dichloroacetic Acid
9.365 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 24.24 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Trichloroacetic Acid
3.8 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
Highest in the ZIP: 21.825 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2019
2/2 SYR4
Dibromoacetic Acid
17.46 µg/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2019
2/2 SYR4
Lithium
10.1 µg/L
No EPA limit set
Highest in the ZIP: CADEVILLE WATER DISTRICT · 6,219 people · 2024
1/2 UCMR-5
Barium
7.985 µg/L 0.4%
of the EPA limit 2000 µg/L
Highest in the ZIP: CADEVILLE WATER DISTRICT · 6,219 people · 2017
1/2 SYR4
Lead
6.7 µg/L 45%
of the EPA limit 15 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
2/2 SYR4
Dalapon
3.184 µg/L 1.6%
of the EPA limit 200 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
2/2 SYR4
Monochloroacetic Acid
2.585 µg/L
No EPA limit set
Highest in the ZIP: CADEVILLE WATER DISTRICT · 6,219 people · 2019
1/2 SYR4
Gross Beta Particle Activity
1.23 pCi/L
No EPA limit set
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
1/2 SYR4
Di(2-ethylhexyl) Phthalate
0.6290 µg/L 10%
of the EPA limit 6 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
Highest in the ZIP: 1.1055 µg/L — CADEVILLE WATER DISTRICT · 6,219 people · 2017
2/2 SYR4
Antimony, Total
1 µg/L 17%
of the EPA limit 6 µg/L
Highest in the ZIP: CADEVILLE WATER DISTRICT · 6,219 people · 2017
1/2 SYR4
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
Highest in the ZIP: CADEVILLE WATER DISTRICT · 6,219 people · 2017
1/2 SYR4
Toluene
0.6600 µg/L 0.1%
of the EPA limit 1000 µg/L
Highest in the ZIP: CADEVILLE WATER DISTRICT · 6,219 people · 2017
1/2 SYR4
Tetrachloroethylene
0.5400 µg/L 11%
of the EPA limit 5 µg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
1/2 SYR4
Combined Radium (-226 And -228)
0.4929 pCi/L 9.9%
of the EPA limit 5 pCi/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2017
1/2 SYR4
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
Main supplier: CHENIERE DREW NORTH WATER SYSTEM · 11,280 people · 2023
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 71225

SupplierStatePopulation served
CHENIERE DREW NORTH WATER SYSTEM LA 11,280
CADEVILLE WATER DISTRICT LA 6,219

Frequently asked questions about ZIP 71225 tap water

Is the tap water in ZIP 71225 safe to drink?

EPA testing detected 26 contaminants across the water suppliers serving ZIP 71225. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 71225?

2 public water suppliers report EPA drinking-water monitoring for ZIP 71225. Each is listed above with its population served.

What contaminants are in ZIP 71225's water?

EPA monitoring detected Fluoride, Copper, TTHM, Nitrate-Nitrite, Total Haloacetic Acids (HAA5), and others across this ZIP's suppliers. The full list with levels and sources is above.