EPA monitoring across the 2 water suppliers serving ZIP 23168 in Virginia detected 23 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

2
water suppliers
57,850
people served
23
contaminants found

What was found in ZIP 23168

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
1822 µg/L 46%
of the EPA limit 4000 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
2/2 SYR4
Copper
176.2 µg/L 14%
of the EPA limit 1300 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
2/2 SYR4
Nitrate-Nitrite
100 µg/L 1%
of the EPA limit 10000 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
TTHM
26 µg/L 33%
of the EPA limit 80 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
2/2 SYR4
Lithium
24.7 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2025
2/2 UCMR-5
Lead
18.2 µg/L 121%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
Bromoform
14.7 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
Barium
11 µg/L 0.5%
of the EPA limit 2000 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
Dibromochloromethane
9.875 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
2/2 SYR4
Gross Beta Particle Activity
8.055 pCi/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2018
2/2 SYR4
Chloroform
2.975 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
Highest in the ZIP: 6.185 µg/L — KINGS VILLAGE - JCSA · 124 people · 2019
2/2 SYR4
Total Haloacetic Acids (HAA5)
3.1 µg/L 5.2%
of the EPA limit 60 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
Highest in the ZIP: 6.025 µg/L — KINGS VILLAGE - JCSA · 124 people · 2019
2/2 SYR4
Xylenes, Total
4.5 µg/L 0%
of the EPA limit 10000 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
Highest in the ZIP: 5.87 µg/L — KINGS VILLAGE - JCSA · 124 people · 2019
2/2 SYR4
Bromodichloromethane
4.435 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
2/2 SYR4
Dichloroacetic Acid
3.1 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
Highest in the ZIP: 4.25 µg/L — KINGS VILLAGE - JCSA · 124 people · 2019
2/2 SYR4
Arsenic
2.95 µg/L 30%
of the EPA limit 10 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
Dibromoacetic Acid
2.84 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
Ethylbenzene
1.1 µg/L 0.2%
of the EPA limit 700 µg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
Highest in the ZIP: 1.625 µg/L — KINGS VILLAGE - JCSA · 124 people · 2019
2/2 SYR4
Trichloroacetic Acid
1.57 µg/L
No EPA limit set
Highest in the ZIP: KINGS VILLAGE - JCSA · 124 people · 2019
1/2 SYR4
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2019
1/2 SYR4
Monochloroacetic Acid
1 µg/L
No EPA limit set
Highest in the ZIP: KINGS VILLAGE - JCSA · 124 people · 2019
1/2 SYR4
Combined Radium (-226 And -228)
0.8650 pCi/L 17%
of the EPA limit 5 pCi/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2018
2/2 SYR4
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: JCSA - CENTRAL SYSTEM · 57,726 people · 2024
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 23168

SupplierStatePopulation served
JCSA - CENTRAL SYSTEM VA 57,726
KINGS VILLAGE - JCSA 124

Frequently asked questions about ZIP 23168 tap water

Is the tap water in ZIP 23168 safe to drink?

EPA testing detected 23 contaminants across the water suppliers serving ZIP 23168. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 23168?

2 public water suppliers report EPA drinking-water monitoring for ZIP 23168. Each is listed above with its population served.

What contaminants are in ZIP 23168's water?

EPA monitoring detected Fluoride, Copper, Nitrate-Nitrite, TTHM, Lithium, and others across this ZIP's suppliers. The full list with levels and sources is above.