← Utah

Tap water quality report

Pleasant Grove City

EPA monitoring tested this supplier for 106 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
19
detected
40,000
people served
20
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Utah

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

20
health-based violations
225
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2023-02-11
TT Health-based Resolved 2023-02-11
TT Health-based Resolved 2023-02-11
TT Health-based Resolved 2023-02-11
MCL Health-based Resolved 2021-08-01 → 2021-08-31
MCL Health-based Resolved 2021-08-01 → 2021-08-31
MCL Health-based Resolved 2021-08-01 → 2021-08-31
MCL Health-based Resolved 2021-08-01 → 2021-08-31
MCL Health-based Resolved 2021-08-01 → 2021-08-31
TT Health-based Resolved 2017-02-25

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
5440 µg/L 54%
of the EPA limit 10000 µg/L
worst single sample: 7100 µg/L
104/104 SYR4 2012–2019
Copper
183.35 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 404 µg/L
92/92 SYR4 2013–2019
Lead
3.155 µg/L 21%
of the EPA limit 15 µg/L
worst single sample: 7.73 µg/L
50/92 SYR4 2013–2019
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
Barium
52.4 µg/L 2.6%
of the EPA limit 2000 µg/L
worst single sample: 54 µg/L
17/17 SYR4 2012–2018
Selenium
11.72 µg/L 23%
of the EPA limit 50 µg/L
worst single sample: 18.2 µg/L
17/17 SYR4 2012–2018
Fluoride
975 µg/L 24%
of the EPA limit 4000 µg/L
worst single sample: 1200 µg/L
16/18 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
5.625 pCi/L 38%
of the EPA limit 15 pCi/L
worst single sample: 5.9 pCi/L
12/17 SYR4 2012–2018
Arsenic
0.9600 µg/L 9.6%
of the EPA limit 10 µg/L
worst single sample: 1 µg/L
9/18 SYR4 2012–2018
Gross Beta Particle Activity
5.12 pCi/L
No EPA limit set
worst single sample: 5.6 pCi/L
9/16 SYR4 2012–2018
TTHM
2.315 µg/L 2.9%
of the EPA limit 80 µg/L
worst single sample: 2.7 µg/L
8/16 SYR4 2012–2019
Bromoform
1.96 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
5/19 SYR4 2012–2019
Dibromochloromethane
0.8700 µg/L
No EPA limit set
worst single sample: 0.9000 µg/L
4/19 SYR4 2012–2019
Cyanide
2 µg/L 1%
of the EPA limit 200 µg/L
3/18 SYR4 2012–2018
Chloroform
1.04 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
3/19 SYR4 2012–2019
Bromodichloromethane
0.5000 µg/L
No EPA limit set
2/19 SYR4 2012–2019
Combined Radium (-226 And -228)
0.9030 pCi/L 18%
of the EPA limit 5 pCi/L
worst single sample: 0.9200 pCi/L
2/2 SYR4 2015–2017
Dibromoacetic Acid
1.3 µg/L
No EPA limit set
1/14 SYR4 2012–2019
Nitrate-Nitrite
671.8 µg/L 6.7%
of the EPA limit 10000 µg/L
1/1 SYR4 2018
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WINTERTON, NEAL
Phone
801-592-2526
Email
[email protected]

Frequently asked questions about Pleasant Grove City

Is Pleasant Grove City tap water safe to drink?

EPA monitoring detected 19 contaminants in Pleasant Grove City's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pleasant Grove City's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Pleasant Grove City serve?

Pleasant Grove City reports serving 40,000 people in Utah, per its EPA record.

Has Pleasant Grove City had any water quality violations?

The EPA has 225 violations on file for Pleasant Grove City, of which 20 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.