← Utah

Tap water quality report

Orem, UT

EPA monitoring detected 24 contaminants across the 4 water suppliers serving Orem. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

4
water suppliers
143,869
people served
24
contaminants found

What was found in Orem's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
362.8 µg/L 9.1%
of the EPA limit 4000 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
Highest in the city: 9460 µg/L — ELK RIDGE TOWN · 5,510 people · 2019
4/4 SYR4
Nitrate
1830 µg/L 18%
of the EPA limit 10000 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
Highest in the city: 5440 µg/L — PLEASANT GROVE CITY · 40,000 people · 2019
4/4 SYR4
Nitrate-Nitrite
338 µg/L 3.4%
of the EPA limit 10000 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2013
Highest in the city: 1400 µg/L — ELK RIDGE TOWN · 5,510 people · 2017
3/4 SYR4
Copper
248.475 µg/L 19%
of the EPA limit 1300 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
4/4 SYR4
Barium
100.15 µg/L 5%
of the EPA limit 2000 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
Highest in the city: 239.2 µg/L — ALPINE COVE WATER SSD · 230 people · 2019
4/4 SYR4
TTHM
49.26 µg/L 62%
of the EPA limit 80 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
2/4 SYR4
Chloroform
36.21 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
2/4 SYR4
Total Haloacetic Acids (HAA5)
30.23 µg/L 50%
of the EPA limit 60 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
1/4 SYR4
Lithium
26.9 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2025
2/4 UCMR-5
Cyanide
22.2 µg/L 11%
of the EPA limit 200 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
4/4 SYR4
Trichloroacetic Acid
16.2 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
1/4 SYR4
Dichloroacetic Acid
14.5 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
1/4 SYR4
Gross Beta Particle Activity
3.72 pCi/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
Highest in the city: 12.54 pCi/L — ALPINE COVE WATER SSD · 230 people · 2019
4/4 SYR4
Selenium
3.818 µg/L 7.6%
of the EPA limit 50 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
Highest in the city: 11.72 µg/L — PLEASANT GROVE CITY · 40,000 people · 2018
3/4 SYR4
Gross Alpha, Excl. Radon And U
3.585 pCi/L 24%
of the EPA limit 15 pCi/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
Highest in the city: 10.72 pCi/L — ALPINE COVE WATER SSD · 230 people · 2019
4/4 SYR4
Bromodichloromethane
10.48 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
2/4 SYR4
Chromium
7.2755 µg/L 7.3%
of the EPA limit 100 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
1/4 SYR4
Lead
7.259 µg/L 48%
of the EPA limit 15 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
4/4 SYR4
Dibromochloromethane
3.16 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
2/4 SYR4
Combined Radium (-226 And -228)
2.35 pCi/L 47%
of the EPA limit 5 pCi/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2017
3/4 SYR4
Arsenic
1.984 µg/L 20%
of the EPA limit 10 µg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2018
3/4 SYR4
Bromoform
1.9 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
Highest in the city: 1.96 µg/L — PLEASANT GROVE CITY · 40,000 people · 2019
2/4 SYR4
Dibromoacetic Acid
1.255 µg/L
No EPA limit set
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2019
Highest in the city: 1.3 µg/L — PLEASANT GROVE CITY · 40,000 people · 2019
2/4 SYR4
Lead
0.0022 mg/L 15%
of the EPA limit 0.0150 mg/L
Main supplier: OREM CITY WATER SYSTEM · 98,129 people · 2024
4/4 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Orem

SupplierPopulation served
OREM CITY WATER SYSTEM 98,129
PLEASANT GROVE CITY 40,000
ELK RIDGE TOWN 5,510
ALPINE COVE WATER SSD 230

Frequently asked questions about Orem tap water

Is Orem tap water safe to drink?

EPA testing detected 24 contaminants in the water serving Orem. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Orem?

4 public water suppliers report drinking-water monitoring for Orem, Utah to the EPA. Each is listed above with its population served.

What contaminants are in Orem's water?

The contaminants EPA monitoring detected in Orem include Fluoride, Nitrate, Nitrate-Nitrite, Copper, Barium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.