← Oklahoma

Tap water quality report

Blue Quail Estates

EPA monitoring tested this supplier for 50 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

50
contaminants tested
16
detected
350
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Canadian

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
321
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 1996-06-01 → 1996-06-30
MCL Health-based Resolved 1996-05-01 → 1996-05-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31
MR Monitoring Resolved 2024-10-01 → 2024-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
5960 µg/L 60%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
806.3 µg/L 62%
of the EPA limit 1300 µg/L
worst single sample: 821 µg/L
15/15 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Lead
16.525 µg/L 110%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 17 µg/L
6/15 SYR4 2013–2019
Chloroform
2.32 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
5/5 SYR4 2012–2019
Bromodichloromethane
2.17 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
4/5 SYR4 2012–2019
Bromoform
2.385 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
4/5 SYR4 2012–2019
Dibromochloromethane
3.1 µg/L
No EPA limit set
4/5 SYR4 2012–2019
TTHM
8.87 µg/L 11%
of the EPA limit 80 µg/L
worst single sample: 8.9 µg/L
4/4 SYR4 2012–2019
Dibromoacetic Acid
2.18 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
3/4 SYR4 2012–2019
Barium
240 µg/L 12%
of the EPA limit 2000 µg/L
1/1 SYR4 2014
Combined Radium (-226 And -228)
0.4940 pCi/L 9.9%
of the EPA limit 5 pCi/L
1/2 SYR4 2012–2018
Dichloroacetic Acid
1.1 µg/L
No EPA limit set
1/4 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
2.312 pCi/L 15%
of the EPA limit 15 pCi/L
1/2 SYR4 2012–2018
Gross Beta Particle Activity
1.768 pCi/L
No EPA limit set
1/2 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
1.5 µg/L 2.5%
of the EPA limit 60 µg/L
1/4 SYR4 2012–2019
34 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChromiumCombined UraniumDichloromethaneEthylbenzeneFluorideMercuryMonobromoacetic AcidMonochloroacetic AcidSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BLUE QUAIL ESTATES
Phone
405-230-7484
Email
[email protected]

Frequently asked questions about Blue Quail Estates

Is Blue Quail Estates tap water safe to drink?

EPA monitoring detected 16 contaminants in Blue Quail Estates's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Blue Quail Estates's water?

EPA monitoring detected Nitrate-Nitrite, Copper, Lead, Lead, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Blue Quail Estates serve?

Blue Quail Estates reports serving 350 people in Oklahoma, per its EPA record.

Has Blue Quail Estates had any water quality violations?

The EPA has 321 violations on file for Blue Quail Estates, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.