← Vermont

Tap water quality report

South Hero, VT

EPA monitoring detected 14 contaminants across the 1 water supplier serving South Hero. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

1
water supplier
760
people served
14
contaminants found

What was found in South Hero's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
682 µg/L 52%
of the EPA limit 1300 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
TTHM
94.745 µg/L 118%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Chloroform
86.25 µg/L
No EPA limit set
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
75.35 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Trichloroacetic Acid
36.45 µg/L
No EPA limit set
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Dichloroacetic Acid
31.45 µg/L
No EPA limit set
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Monochloroacetic Acid
12.95 µg/L
No EPA limit set
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Lead
8 µg/L 53%
of the EPA limit 15 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Bromodichloromethane
6.145 µg/L
No EPA limit set
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Asbestos
2 MFL 29%
of the EPA limit 7 MFL
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2013
1/1 SYR4
Hexachlorocyclopentadiene
0.2320 µg/L 0.5%
of the EPA limit 50 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Atrazine
0.1480 µg/L 4.9%
of the EPA limit 3 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Methoxychlor
0.1000 µg/L 0.3%
of the EPA limit 40 µg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2019
1/1 SYR4
Lead
0.0034 mg/L 23%
of the EPA limit 0.0150 mg/L
Main supplier: SOUTH HERO FIRE DISTRICT 4 · 760 people · 2025
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving South Hero

SupplierPopulation served
SOUTH HERO FIRE DISTRICT 4 760

Frequently asked questions about South Hero tap water

Is South Hero tap water safe to drink?

EPA testing detected 14 contaminants in the water serving South Hero. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve South Hero?

1 public water supplier report drinking-water monitoring for South Hero, Vermont to the EPA. Each is listed above with its population served.

What contaminants are in South Hero's water?

The contaminants EPA monitoring detected in South Hero include Copper, TTHM, Chloroform, Total Haloacetic Acids (HAA5), Trichloroacetic Acid. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.