← Texas

Tap water quality report

Willis, TX

EPA monitoring detected 26 contaminants across the 15 water suppliers serving Willis. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

15
water suppliers
23,287
people served
26
contaminants found

What was found in Willis's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
100.96 µg/L 7.8%
of the EPA limit 1300 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2018
Highest in the city: 2184 µg/L — TIMBER LINE ESTATES · 579 people · 2019
15/15 SYR4
Fluoride
1568 µg/L 39%
of the EPA limit 4000 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
15/15 SYR4
Barium
222.3 µg/L 11%
of the EPA limit 2000 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
Highest in the city: 316.9 µg/L — CREEKSIDE ACRES WATER SYSTEM · 567 people · 2019
15/15 SYR4
Lithium
199 µg/L
No EPA limit set
Main supplier: CITY OF WILLIS · 14,133 people · 2025
1/15 UCMR-5
Nitrate
60 µg/L 0.6%
of the EPA limit 10000 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
11/15 SYR4
Nitrate-Nitrite
57.5 µg/L 0.6%
of the EPA limit 10000 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2015
10/15 SYR4
TTHM
55.2 µg/L 69%
of the EPA limit 80 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
9/15 SYR4
Bromoform
41.525 µg/L
No EPA limit set
Main supplier: CITY OF WILLIS · 14,133 people · 2019
6/15 SYR4
Lead
6.358 µg/L 42%
of the EPA limit 15 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2018
Highest in the city: 36.75 µg/L — CAPE MALIBU WSC · 250 people · 2017
14/15 SYR4
Nitrite
30 µg/L 3%
of the EPA limit 1000 µg/L
Highest in the city: CREEKSIDE ACRES WATER SYSTEM · 567 people · 2015
3/15 SYR4
Gross Beta Particle Activity
7.71 pCi/L
No EPA limit set
Main supplier: CITY OF WILLIS · 14,133 people · 2019
Highest in the city: 14.08 pCi/L — BRIDGEPOINT SUBDIVISION · 291 people · 2019
15/15 SYR4
Dibromochloromethane
13.6 µg/L
No EPA limit set
Main supplier: CITY OF WILLIS · 14,133 people · 2019
9/15 SYR4
Combined Uranium
9.7 µg/L 32%
of the EPA limit 30 µg/L
Highest in the city: ROGERS ROAD WATER SYSTEM · 567 people · 2018
2/15 SYR4
Gross Alpha, Excl. Radon And U
6.18 pCi/L 41%
of the EPA limit 15 pCi/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
Highest in the city: 7.44 pCi/L — CAPE MALIBU WSC · 250 people · 2019
9/15 SYR4
Selenium
6.97 µg/L 14%
of the EPA limit 50 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
2/15 SYR4
Chloroform
6.38 µg/L
No EPA limit set
Highest in the city: TIMBER LINE ESTATES · 579 people · 2019
7/15 SYR4
Dibromoacetic Acid
5.75 µg/L
No EPA limit set
Main supplier: CITY OF WILLIS · 14,133 people · 2019
1/15 SYR4
Total Haloacetic Acids (HAA5)
5.75 µg/L 9.6%
of the EPA limit 60 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
4/15 SYR4
Arsenic
2.58 µg/L 26%
of the EPA limit 10 µg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2019
Highest in the city: 5.245 µg/L — TIMBER LINE ESTATES · 579 people · 2017
6/15 SYR4
Xylenes, Total
4.1 µg/L 0%
of the EPA limit 10000 µg/L
Highest in the city: ROGERS ROAD WATER SYSTEM · 567 people · 2019
2/15 SYR4
Combined Radium (-226 And -228)
1.413 pCi/L 28%
of the EPA limit 5 pCi/L
Main supplier: CITY OF WILLIS · 14,133 people · 2016
Highest in the city: 3.8 pCi/L — TIMBER LINE ESTATES · 579 people · 2014
11/15 SYR4
Bromodichloromethane
3 µg/L
No EPA limit set
Main supplier: CITY OF WILLIS · 14,133 people · 2019
9/15 SYR4
Dichloroacetic Acid
1.6 µg/L
No EPA limit set
Highest in the city: BRIDGEPOINT SUBDIVISION · 291 people · 2019
3/15 SYR4
Di(2-ethylhexyl) Phthalate
1.5 µg/L 25%
of the EPA limit 6 µg/L
Highest in the city: ROGERS ROAD WATER SYSTEM · 567 people · 2019
2/15 SYR4
Ethylbenzene
0.6000 µg/L 0.1%
of the EPA limit 700 µg/L
Highest in the city: ROGERS ROAD WATER SYSTEM · 567 people · 2019
1/15 SYR4
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
Main supplier: CITY OF WILLIS · 14,133 people · 2025
Highest in the city: 0.0070 mg/L — CREEKSIDE ACRES WATER SYSTEM · 567 people · 2025
15/15 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Willis

Frequently asked questions about Willis tap water

Is Willis tap water safe to drink?

EPA testing detected 26 contaminants in the water serving Willis. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Willis?

15 public water suppliers report drinking-water monitoring for Willis, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Willis's water?

The contaminants EPA monitoring detected in Willis include Copper, Fluoride, Barium, Lithium, Nitrate. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.