← Texas

Tap water quality report

Ingleside, TX

EPA monitoring detected 31 contaminants across the 3 water suppliers serving Ingleside. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

3
water suppliers
10,764
people served
31
contaminants found

What was found in Ingleside's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Chlorite
938 µg/L 94%
of the EPA limit 1000 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Nitrate
852.5 µg/L 8.5%
of the EPA limit 10000 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Fluoride
613 µg/L 15%
of the EPA limit 4000 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Nitrate-Nitrite
573.4 µg/L 5.7%
of the EPA limit 10000 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2015
1/3 SYR4
Copper
407.95 µg/L 31%
of the EPA limit 1300 µg/L
Main supplier: CITY OF INGLESIDE · 10,106 people · 2017
3/3 SYR4
Barium
138.1 µg/L 6.9%
of the EPA limit 2000 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Cyanide
107 µg/L 54%
of the EPA limit 200 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
TTHM
52.325 µg/L 65%
of the EPA limit 80 µg/L
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 67.925 µg/L — SAN PATRICIO MWD · 48 people · 2019
3/3 SYR4
Total Haloacetic Acids (HAA5)
33.37 µg/L 56%
of the EPA limit 60 µg/L
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 34.7 µg/L — CITY OF INGLESIDE ON THE BAY · 610 people · 2019
3/3 SYR4
Bromoform
27.535 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 31.58 µg/L — SAN PATRICIO MWD · 48 people · 2019
3/3 SYR4
Lithium
27.4 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2024
1/3 UCMR-5
Dibromoacetic Acid
18.59 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 22.79 µg/L — SAN PATRICIO MWD · 48 people · 2019
3/3 SYR4
Dichloroacetic Acid
19.885 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 20.75 µg/L — CITY OF INGLESIDE ON THE BAY · 610 people · 2019
3/3 SYR4
Dibromochloromethane
16.59 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 18.65 µg/L — SAN PATRICIO MWD · 48 people · 2019
3/3 SYR4
Bromodichloromethane
12.78 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
3/3 SYR4
Lead
4.366 µg/L 29%
of the EPA limit 15 µg/L
Main supplier: CITY OF INGLESIDE · 10,106 people · 2017
Highest in the city: 11.14 µg/L — CITY OF INGLESIDE ON THE BAY · 610 people · 2017
3/3 SYR4
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2015
1/3 SYR4
Gross Beta Particle Activity
9.59 pCi/L
No EPA limit set
Highest in the city: SAN PATRICIO MWD · 48 people · 2018
1/3 SYR4
Chloroform
7.505 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
3/3 SYR4
Monochloroacetic Acid
5.06 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
Highest in the city: 6.97 µg/L — CITY OF INGLESIDE ON THE BAY · 610 people · 2019
3/3 SYR4
Monobromoacetic Acid
6.5 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
3/3 SYR4
Selenium
4.275 µg/L 8.6%
of the EPA limit 50 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Arsenic
3.38 µg/L 34%
of the EPA limit 10 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Trichloroacetic Acid
2.63 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2019
3/3 SYR4
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2012
1/3 SYR4
Dichloromethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Atrazine
0.3400 µg/L 11%
of the EPA limit 3 µg/L
Highest in the city: SAN PATRICIO MWD · 48 people · 2019
1/3 SYR4
Lead
0.0123 mg/L 82%
of the EPA limit 0.0150 mg/L
Main supplier: CITY OF INGLESIDE · 10,106 people · 2026
3/3 LCR
Pfba
0.0082 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2025
1/3 UCMR-5
Pfpea
0.0037 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2025
1/3 UCMR-5
PFBS
0.0030 µg/L
No EPA limit set
Main supplier: CITY OF INGLESIDE · 10,106 people · 2025
1/3 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Ingleside

SupplierPopulation served
CITY OF INGLESIDE 10,106
CITY OF INGLESIDE ON THE BAY 610
SAN PATRICIO MWD 48

Frequently asked questions about Ingleside tap water

Is Ingleside tap water safe to drink?

EPA testing detected 31 contaminants in the water serving Ingleside. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Ingleside?

3 public water suppliers report drinking-water monitoring for Ingleside, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Ingleside's water?

The contaminants EPA monitoring detected in Ingleside include Chlorite, Nitrate, Fluoride, Nitrate-Nitrite, Copper. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.