← Texas

Tap water quality report

Borger, TX

EPA monitoring detected 29 contaminants across the 3 water suppliers serving Borger. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

3
water suppliers
14,705
people served
29
contaminants found

What was found in Borger's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
1960 µg/L 20%
of the EPA limit 10000 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
2/3 SYR4
Fluoride
1731.5 µg/L 43%
of the EPA limit 4000 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
Highest in the city: 1760 µg/L — TCW SUPPLY · 2,220 people · 2019
2/3 SYR4
Nitrate-Nitrite
1715 µg/L 17%
of the EPA limit 10000 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2017
2/3 SYR4
Copper
225 µg/L 17%
of the EPA limit 1300 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2017
Highest in the city: 355 µg/L — GRACED LAND EAST · 66 people · 2017
3/3 SYR4
Barium
121.4 µg/L 6.1%
of the EPA limit 2000 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
2/3 SYR4
Lithium
80.7 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2023
1/3 UCMR-5
Trichloroacetic Acid
10.3 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
1/3 SYR4
Total Haloacetic Acids (HAA5)
10.215 µg/L 17%
of the EPA limit 60 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
3/3 SYR4
Monochloroacetic Acid
9.64 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
3/3 SYR4
Lead
9.08 µg/L 61%
of the EPA limit 15 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2017
3/3 SYR4
Gross Beta Particle Activity
7.31 pCi/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2017
Highest in the city: 7.665 pCi/L — TCW SUPPLY · 2,220 people · 2018
2/3 SYR4
Combined Uranium
7.12 µg/L 24%
of the EPA limit 30 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2017
2/3 SYR4
Dichloroacetic Acid
7.1 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
3/3 SYR4
Cyanide
6.91 µg/L 3.5%
of the EPA limit 200 µg/L
Highest in the city: TCW SUPPLY · 2,220 people · 2019
1/3 SYR4
Gross Alpha, Excl. Radon And U
6.7 pCi/L 45%
of the EPA limit 15 pCi/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2017
Highest in the city: 6.75 pCi/L — TCW SUPPLY · 2,220 people · 2018
2/3 SYR4
TTHM
5.664 µg/L 7.1%
of the EPA limit 80 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
3/3 SYR4
Monobromoacetic Acid
4.9 µg/L
No EPA limit set
Highest in the city: GRACED LAND EAST · 66 people · 2018
1/3 SYR4
Chromium
4.76 µg/L 4.8%
of the EPA limit 100 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
2/3 SYR4
Bromoform
4.524 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
3/3 SYR4
Selenium
4.1 µg/L 8.2%
of the EPA limit 50 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
2/3 SYR4
Xylenes, Total
3.472 µg/L 0%
of the EPA limit 10000 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
1/3 SYR4
Arsenic
2.87 µg/L 29%
of the EPA limit 10 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
2/3 SYR4
Dibromochloromethane
2.736 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
2/3 SYR4
Chloroform
2.07 µg/L
No EPA limit set
Highest in the city: GRACED LAND EAST · 66 people · 2019
1/3 SYR4
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
1/3 SYR4
Bromodichloromethane
0.5000 µg/L
No EPA limit set
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
Highest in the city: 1.03 µg/L — GRACED LAND EAST · 66 people · 2019
2/3 SYR4
Ethylbenzene
0.6543 µg/L 0.1%
of the EPA limit 700 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
1/3 SYR4
Di(2-ethylhexyl) Phthalate
0.6000 µg/L 10%
of the EPA limit 6 µg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2019
1/3 SYR4
Lead
0.0017 mg/L 11%
of the EPA limit 0.0150 mg/L
Main supplier: BORGER MUNICIPAL WATER SYSTEM · 12,419 people · 2023
Highest in the city: 0.0117 mg/L — GRACED LAND EAST · 66 people · 2025
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Borger

SupplierPopulation served
BORGER MUNICIPAL WATER SYSTEM 12,419
TCW SUPPLY 2,220
GRACED LAND EAST 66

Frequently asked questions about Borger tap water

Is Borger tap water safe to drink?

EPA testing detected 29 contaminants in the water serving Borger. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Borger?

3 public water suppliers report drinking-water monitoring for Borger, Texas to the EPA. Each is listed above with its population served.

What contaminants are in Borger's water?

The contaminants EPA monitoring detected in Borger include Nitrate, Fluoride, Nitrate-Nitrite, Copper, Barium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.