← Connecticut

Tap water quality report

Cheshire, CT

EPA monitoring detected 38 contaminants across the 4 water suppliers serving Cheshire. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

4
water suppliers
520,494
people served
38
contaminants found

What was found in Cheshire's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate-Nitrite
3227.6 µg/L 32%
of the EPA limit 10000 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 6700 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Nitrate
3102 µg/L 31%
of the EPA limit 10000 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 6600 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Fluoride
1020 µg/L 26%
of the EPA limit 4000 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 1350 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Barium
246.8 µg/L 12%
of the EPA limit 2000 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 520.55 µg/L — MERIDEN WATER DIVISION · 58,441 people · 2019
4/4 SYR4
Nitrite
442.2 µg/L 44%
of the EPA limit 1000 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
4/4 SYR4
Copper
270 µg/L 21%
of the EPA limit 1300 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 429 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
TTHM
81.905 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 83 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Chloroform
70.9 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
3/4 SYR4
Total Haloacetic Acids (HAA5)
57.575 µg/L 96%
of the EPA limit 60 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 58.85 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Lead
44.2 µg/L 295%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
3/4 SYR4
Trichloroacetic Acid
31.09 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 35.4 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
3/4 SYR4
Dichloroacetic Acid
21.85 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 34 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
3/4 SYR4
Bromodichloromethane
13.39 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
4/4 SYR4
Lithium
9.01 µg/L
No EPA limit set
Highest in the city: SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2024
1/4 UCMR-5
Gross Beta Particle Activity
8.5 pCi/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
2/4 SYR4
Combined Uranium
6.49 µg/L 22%
of the EPA limit 30 µg/L
Highest in the city: CRESTVIEW CONDOMINIUM ASSOCIATION · 84 people · 2019
3/4 SYR4
Tetrachloroethylene
6.312 µg/L 126%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
Highest in the city: SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
1/4 SYR4
Monochloroacetic Acid
6.1 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
3/4 SYR4
Dibromochloromethane
3.2 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 5.6 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Arsenic
5.5 µg/L 55%
of the EPA limit 10 µg/L
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2019
1/4 SYR4
Cyanide
5 µg/L 2.5%
of the EPA limit 200 µg/L
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2019
1/4 SYR4
Monobromoacetic Acid
4.5 µg/L
No EPA limit set
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2019
1/4 SYR4
Gross Alpha, Excl. Radon And U
4.353 pCi/L 29%
of the EPA limit 15 pCi/L
Highest in the city: CRESTVIEW CONDOMINIUM ASSOCIATION · 84 people · 2019
2/4 SYR4
Bromoform
0.7500 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 2.7 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2019
4/4 SYR4
Dibromoacetic Acid
0.8000 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 2.5 µg/L — MERIDEN WATER DIVISION · 58,441 people · 2019
3/4 SYR4
Chromium
1.5 µg/L 1.5%
of the EPA limit 100 µg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 1.9 µg/L — MERIDEN WATER DIVISION · 58,441 people · 2019
3/4 SYR4
Combined Radium (-226 And -228)
1.549 pCi/L 31%
of the EPA limit 5 pCi/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2019
Highest in the city: 1.61 pCi/L — MERIDEN WATER DIVISION · 58,441 people · 2019
4/4 SYR4
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2019
1/4 SYR4
Trichloroethylene
0.5400 µg/L 11%
of the EPA limit 5 µg/L
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2019
1/4 SYR4
PFOS
0.0107 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2024
3/4 UCMR-5
PFOA
0.0071 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2024
Highest in the city: 0.0080 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2024
3/4 UCMR-5
Pfhxa
0.0058 µg/L
No EPA limit set
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2024
2/4 UCMR-5
Pfba
0.0050 µg/L
No EPA limit set
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2024
2/4 UCMR-5
Pfpea
0.0031 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2024
Highest in the city: 0.0048 µg/L — MERIDEN WATER DIVISION · 58,441 people · 2024
3/4 UCMR-5
PFBS
0.0035 µg/L
No EPA limit set
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2024
Highest in the city: 0.0040 µg/L — SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2024
3/4 UCMR-5
PFHXS
0.0040 µg/L
No EPA limit set
Highest in the city: MERIDEN WATER DIVISION · 58,441 people · 2024
1/4 UCMR-5
Pfhpa
0.0030 µg/L
No EPA limit set
Highest in the city: SOUTHINGTON WATER DEPARTMENT · 43,069 people · 2024
1/4 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: REGIONAL WATER AUTHORITY · 418,900 people · 2026
4/4 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Cheshire

Frequently asked questions about Cheshire tap water

Is Cheshire tap water safe to drink?

EPA testing detected 38 contaminants in the water serving Cheshire. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Cheshire?

4 public water suppliers report drinking-water monitoring for Cheshire, Connecticut to the EPA. Each is listed above with its population served.

What contaminants are in Cheshire's water?

The contaminants EPA monitoring detected in Cheshire include Nitrate-Nitrite, Nitrate, Fluoride, Barium, Nitrite. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.