← Guilderland, NY

Tap water quality report

ZIP 12084 — Guilderland, NY

EPA monitoring across the 1 water supplier serving ZIP 12084 in Guilderland, NY detected 19 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

1
water supplier
30,000
people served
19
contaminants found

What was found in ZIP 12084

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2260 µg/L 23%
of the EPA limit 10000 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Fluoride
938 µg/L 23%
of the EPA limit 4000 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Barium
168 µg/L 8.4%
of the EPA limit 2000 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
TTHM
110.8 µg/L 139%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Chloroform
97.175 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
68.05 µg/L 113%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Cyanide
47.59 µg/L 24%
of the EPA limit 200 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Trichloroacetic Acid
47.57 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Dichloroacetic Acid
22.95 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Bromodichloromethane
14.05 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Monochloroacetic Acid
4.17 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Dibromochloromethane
3.59 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Combined Radium (-226 And -228)
2.58 pCi/L 52%
of the EPA limit 5 pCi/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2017
1/1 SYR4
Monobromoacetic Acid
1.736 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Dibromoacetic Acid
1.42 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Bromoform
1.1 µg/L
No EPA limit set
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Arsenic
0.5000 µg/L 5%
of the EPA limit 10 µg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2019
1/1 SYR4
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
Main supplier: GUILDERLAND TOWN WD · 30,000 people · 2023
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 12084

SupplierStatePopulation served
GUILDERLAND TOWN WD NY 30,000

Frequently asked questions about ZIP 12084 tap water

Is the tap water in ZIP 12084 safe to drink?

EPA testing detected 19 contaminants across the water suppliers serving ZIP 12084. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 12084?

1 public water supplier report EPA drinking-water monitoring for ZIP 12084. Each is listed above with its population served.

What contaminants are in ZIP 12084's water?

EPA monitoring detected Nitrate, Fluoride, Barium, TTHM, Chloroform, and others across this ZIP's suppliers. The full list with levels and sources is above.