← Wyoming

Tap water quality report

Y-O Investments, Inc.

EPA monitoring tested this supplier for 80 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
15
detected
173
people served
12
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Platte

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
37
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2009-08-01 → 2009-08-31
MCL Health-based Resolved 2009-08-01 → 2009-08-31
MCL Health-based Resolved 2009-08-01 → 2009-08-31
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Resolved 2009-07-01 → 2009-07-31
MCL Health-based Archived 1998-10-01 → 1998-10-31
MCL Health-based Archived 1998-06-01 → 1998-06-30
MCL Health-based Archived 1997-08-01 → 1997-08-31
MCL Health-based Archived 1997-07-01 → 1997-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
3900 µg/L 39%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
209.5 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 298 µg/L
11/11 SYR4 2014–2017
Combined Uranium
38.36 µg/L 128%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 42 µg/L
9/9 SYR4 2016–2018
Gross Alpha, Excl. Radon And U
8.9 pCi/L 59%
of the EPA limit 15 pCi/L
worst single sample: 9.3 pCi/L
6/8 SYR4 2016–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
6/6 LCR 2023
Combined Radium (-226 And -228)
1.77 pCi/L 35%
of the EPA limit 5 pCi/L
worst single sample: 1.8 pCi/L
4/8 SYR4 2016–2018
Bromoform
11.12 µg/L
No EPA limit set
worst single sample: 12 µg/L
3/5 SYR4 2014–2019
Fluoride
600 µg/L 15%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2019
Selenium
6 µg/L 12%
of the EPA limit 50 µg/L
3/3 SYR4 2013–2019
TTHM
13.011 µg/L 16%
of the EPA limit 80 µg/L
worst single sample: 14 µg/L
3/6 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
2.652 µg/L 4.4%
of the EPA limit 60 µg/L
worst single sample: 2.8 µg/L
3/4 SYR4 2012–2018
Arsenic
2.95 µg/L 30%
of the EPA limit 10 µg/L
worst single sample: 3 µg/L
2/3 SYR4 2013–2019
Dibromoacetic Acid
2.71 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
2/3 SYR4 2014–2018
Dibromochloromethane
1.657 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
2/5 SYR4 2014–2019
Gross Beta Particle Activity
6.135 pCi/L
No EPA limit set
worst single sample: 6.2 pCi/L
2/2 SYR4 2017
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SMITH, JANICE
Phone
307-699-0232
Email
[email protected]

Frequently asked questions about Y-O Investments, Inc.

Is Y-O Investments, Inc. tap water safe to drink?

EPA monitoring detected 15 contaminants in Y-O Investments, Inc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Y-O Investments, Inc.'s water?

EPA monitoring detected Nitrate-Nitrite, Copper, Combined Uranium, Gross Alpha, Excl. Radon And U, Lead, and others. The full list with the level and data source for each is above.

How many people does Y-O Investments, Inc. serve?

Y-O Investments, Inc. reports serving 173 people in Wyoming, per its EPA record.

Has Y-O Investments, Inc. had any water quality violations?

The EPA has 37 violations on file for Y-O Investments, Inc., of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.