← Wyoming

Tap water quality report

Cheyenne Board of Public Utilities

EPA monitoring tested this supplier for 76 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
15
detected
64,165
people served
2
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Laramie

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
9
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1991-05-01 → 1991-05-31
MCL Health-based Archived 1991-05-01 → 1991-05-31
MR Monitoring Archived 1996-09-01 → 1996-09-30
MR Monitoring Archived 1995-07-01 → 1995-07-31
MR Monitoring Resolved 1994-07-01
MR Monitoring Archived 1994-03-01 → 1994-03-31
MR Monitoring Archived 1993-10-01 → 1993-10-31
MR Monitoring Archived 1993-06-01 → 1993-06-30
MR Monitoring Archived 1991-05-01 → 1991-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
57.3 µg/L 72%
of the EPA limit 80 µg/L
worst single sample: 75.6 µg/L
248/248 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
33.325 µg/L 56%
of the EPA limit 60 µg/L
worst single sample: 44 µg/L
248/248 SYR4 2012–2019
Nitrate
700 µg/L 7%
of the EPA limit 10000 µg/L
worst single sample: 800 µg/L
44/44 SYR4 2012–2019
Copper
450 µg/L 35%
of the EPA limit 1300 µg/L
worst single sample: 920 µg/L
30/30 SYR4 2017
Barium
47 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 57 µg/L
21/21 SYR4 2012–2019
Nitrate-Nitrite
705 µg/L 7%
of the EPA limit 10000 µg/L
worst single sample: 800 µg/L
20/20 SYR4 2012–2019
Fluoride
610 µg/L 15%
of the EPA limit 4000 µg/L
worst single sample: 700 µg/L
19/21 SYR4 2012–2019
Lead
100.1 µg/L 667%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 380 µg/L
16/30 SYR4 2017
Gross Alpha, Excl. Radon And U
6.33 pCi/L 42%
of the EPA limit 15 pCi/L
worst single sample: 10.1 pCi/L
14/14 SYR4 2012–2018
Lead
0.0150 mg/L 100%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Combined Radium (-226 And -228)
4.2 pCi/L 84%
of the EPA limit 5 pCi/L
12/13 SYR4 2012–2018
Combined Uranium
6.2878 µg/L 21%
of the EPA limit 30 µg/L
12/13 SYR4 2012–2018
Arsenic
1.5 µg/L 15%
of the EPA limit 10 µg/L
1/21 SYR4 2012–2019
Endothall
9 µg/L 9%
of the EPA limit 100 µg/L
1/18 SYR4 2012–2019
Gross Beta Particle Activity
3.2 pCi/L
No EPA limit set
1/1 SYR4 2015
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromateChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BASSETT, CLINT
Phone
307-632-9890
Email
[email protected]

Frequently asked questions about Cheyenne Board of Public Utilities

Is Cheyenne Board of Public Utilities tap water safe to drink?

EPA monitoring detected 15 contaminants in Cheyenne Board of Public Utilities's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cheyenne Board of Public Utilities's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Copper, Barium, and others. The full list with the level and data source for each is above.

How many people does Cheyenne Board of Public Utilities serve?

Cheyenne Board of Public Utilities reports serving 64,165 people in Wyoming, per its EPA record.

Has Cheyenne Board of Public Utilities had any water quality violations?

The EPA has 9 violations on file for Cheyenne Board of Public Utilities, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.