← West Virginia

Tap water quality report

Mason Water Dept

EPA monitoring tested this supplier for 75 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
20
detected
1,679
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Mason

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
487
violations on file
15
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2009-12-01 → 2009-12-31
TT Health-based Resolved 2009-12-01 → 2009-12-31
TT Health-based Resolved 2009-12-01 → 2009-12-31
TT Health-based Resolved 2009-12-01 → 2009-12-31
Other Monitoring Unaddressed 2025-11-15
Other Monitoring Unaddressed 2025-11-15
MR Monitoring Archived 2025-10-01 → 2025-10-31
MR Monitoring Archived 2025-10-01 → 2025-10-31
MR Monitoring Unaddressed 2025-10-01
MR Monitoring Unaddressed 2025-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
251.4 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 311 µg/L
45/45 SYR4 2013–2019
Lead
3.985 µg/L 27%
of the EPA limit 15 µg/L
worst single sample: 4.8 µg/L
44/45 SYR4 2013–2019
Nitrate
6522 µg/L 65%
of the EPA limit 10000 µg/L
worst single sample: 6860 µg/L
34/34 SYR4 2012–2019
Lead
0.0053 mg/L 35%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
TTHM
3.285 µg/L 4.1%
of the EPA limit 80 µg/L
worst single sample: 3.7 µg/L
6/8 SYR4 2012–2019
Dibromochloromethane
1.306 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
5/8 SYR4 2012–2019
Bromodichloromethane
1.046 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
4/8 SYR4 2012–2019
Barium
63.89 µg/L 3.2%
of the EPA limit 2000 µg/L
worst single sample: 64.2 µg/L
3/3 SYR4 2012–2019
Chloroform
0.5770 µg/L
No EPA limit set
worst single sample: 0.6000 µg/L
3/8 SYR4 2012–2019
Fluoride
376 µg/L 9.4%
of the EPA limit 4000 µg/L
worst single sample: 400 µg/L
3/3 SYR4 2012–2019
Antimony, Total
0.6750 µg/L 11%
of the EPA limit 6 µg/L
worst single sample: 0.7000 µg/L
2/3 SYR4 2012–2019
Bromoform
0.8850 µg/L
No EPA limit set
worst single sample: 0.9000 µg/L
2/8 SYR4 2012–2019
Dibromoacetic Acid
5.0515 µg/L
No EPA limit set
worst single sample: 5.19 µg/L
2/8 SYR4 2012–2019
Dichloroacetic Acid
11.116 µg/L
No EPA limit set
worst single sample: 11.6 µg/L
2/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
26.9045 µg/L 45%
of the EPA limit 60 µg/L
worst single sample: 27.8 µg/L
2/8 SYR4 2012–2019
Chromium
1.2 µg/L 1.2%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2019
Combined Radium (-226 And -228)
0.2210 pCi/L 4.4%
of the EPA limit 5 pCi/L
1/1 SYR4 2014
Gross Beta Particle Activity
1.31 pCi/L
No EPA limit set
1/1 SYR4 2014
Monochloroacetic Acid
2.78 µg/L
No EPA limit set
1/8 SYR4 2012–2019
Trichloroacetic Acid
13.8 µg/L
No EPA limit set
1/8 SYR4 2012–2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CLARK, KRISTOPHER
Phone
304-773-5574

Frequently asked questions about Mason Water Dept

Is Mason Water Dept tap water safe to drink?

EPA monitoring detected 20 contaminants in Mason Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mason Water Dept's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, TTHM, and others. The full list with the level and data source for each is above.

How many people does Mason Water Dept serve?

Mason Water Dept reports serving 1,679 people in West Virginia, per its EPA record.

Has Mason Water Dept had any water quality violations?

The EPA has 487 violations on file for Mason Water Dept, of which 4 are health-based (a contaminant limit or required treatment was breached) and 15 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.