← West Virginia

Tap water quality report

Southern Jackson County P S D

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
6,070
people served
207
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Jackson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

207
health-based violations
254
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Resolved 2020-01-01 → 2020-03-31
MCL Health-based Archived 2016-07-01 → 2016-09-30
MCL Health-based Archived 2016-07-01 → 2016-09-30
MCL Health-based Archived 2016-07-01 → 2016-09-30
MCL Health-based Archived 2016-04-01 → 2016-06-30
MCL Health-based Archived 2016-04-01 → 2016-06-30
MCL Health-based Archived 2016-04-01 → 2016-06-30
MCL Health-based Archived 2016-01-01 → 2016-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
13.45 µg/L
No EPA limit set
worst single sample: 17 µg/L
55/55 SYR4 2012–2019
Chloroform
95.7 µg/L
No EPA limit set
worst single sample: 100 µg/L
55/55 SYR4 2012–2019
TTHM
110 µg/L 138%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 116.77 µg/L
55/55 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
101 µg/L 168%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 214 µg/L
55/55 SYR4 2012–2019
Dichloroacetic Acid
39.94 µg/L
No EPA limit set
worst single sample: 89.7 µg/L
54/55 SYR4 2012–2019
Trichloroacetic Acid
65.42 µg/L
No EPA limit set
worst single sample: 94.9 µg/L
54/55 SYR4 2012–2019
Monochloroacetic Acid
7.4925 µg/L
No EPA limit set
worst single sample: 28.9 µg/L
46/55 SYR4 2012–2019
Dibromochloromethane
1.585 µg/L
No EPA limit set
worst single sample: 4.73 µg/L
44/55 SYR4 2012–2019
Copper
605.05 µg/L 47%
of the EPA limit 1300 µg/L
worst single sample: 2130 µg/L
40/40 SYR4 2013–2019
Lead
4.08 µg/L 27%
of the EPA limit 15 µg/L
worst single sample: 6.6 µg/L
39/40 SYR4 2013–2019
Lead
0.0043 mg/L 29%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Monobromoacetic Acid
10.865 µg/L
No EPA limit set
worst single sample: 13.8 µg/L
6/55 SYR4 2012–2019
Dibromoacetic Acid
1.515 µg/L
No EPA limit set
worst single sample: 1.62 µg/L
3/55 SYR4 2012–2019
Bromoform
0.5830 µg/L
No EPA limit set
worst single sample: 0.6000 µg/L
2/55 SYR4 2012–2019

Utility contact

Contact
VIELHABER, KARL
Phone
304-372-2622

Frequently asked questions about Southern Jackson County P S D

Is Southern Jackson County P S D tap water safe to drink?

EPA monitoring detected 14 contaminants in Southern Jackson County P S D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Southern Jackson County P S D's water?

EPA monitoring detected Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Southern Jackson County P S D serve?

Southern Jackson County P S D reports serving 6,070 people in West Virginia, per its EPA record.

Has Southern Jackson County P S D had any water quality violations?

The EPA has 254 violations on file for Southern Jackson County P S D, of which 207 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.