← Vermont

Tap water quality report

St Albans Water Dept

EPA monitoring tested this supplier for 104 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
12
detected
10,200
people served
11
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Franklin

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

11
health-based violations
58
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Addressed 2024-10-17
TT Health-based Addressed 2024-10-17
TT Health-based Addressed 2024-10-17
MCL Health-based Resolved 1996-09-01 → 1996-09-30
MCL Health-based Resolved 1996-09-01 → 1996-09-30
MCL Health-based Resolved 1996-09-01 → 1996-09-30
MCL Health-based Resolved 1996-09-01 → 1996-09-30
MCL Health-based Resolved 1996-09-01 → 1996-09-30
TT Health-based Resolved 1992-01-01
TT Health-based Resolved 1992-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
800 µg/L 20%
of the EPA limit 4000 µg/L
worst single sample: 1100 µg/L
394/397 SYR4 2012–2019
Bromodichloromethane
5.03 µg/L
No EPA limit set
worst single sample: 7.1 µg/L
115/115 SYR4 2012–2019
Chloroform
52.12 µg/L
No EPA limit set
worst single sample: 74.6 µg/L
115/115 SYR4 2012–2019
Dichloroacetic Acid
18.32 µg/L
No EPA limit set
worst single sample: 23 µg/L
99/99 SYR4 2012–2019
TTHM
58.51 µg/L 73%
of the EPA limit 80 µg/L
worst single sample: 81.7 µg/L
99/99 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
45.94 µg/L 77%
of the EPA limit 60 µg/L
worst single sample: 54.1 µg/L
99/99 SYR4 2012–2019
Trichloroacetic Acid
28.41 µg/L
No EPA limit set
worst single sample: 32.3 µg/L
99/99 SYR4 2012–2019
Copper
285.5 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 320 µg/L
70/71 SYR4 2012–2018
Nitrate
418 µg/L 4.2%
of the EPA limit 10000 µg/L
worst single sample: 440 µg/L
32/32 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
28/28 LCR 2024
Lead
39.75 µg/L 265%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 61 µg/L
18/71 SYR4 2012–2018
Combined Radium (-226 And -228)
0.6410 pCi/L 13%
of the EPA limit 5 pCi/L
worst single sample: 0.6620 pCi/L
4/4 SYR4 2014–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MULHERON, MATT R
Phone
802-309-1815
Email
[email protected]

Frequently asked questions about St Albans Water Dept

Is St Albans Water Dept tap water safe to drink?

EPA monitoring detected 12 contaminants in St Albans Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in St Albans Water Dept's water?

EPA monitoring detected Fluoride, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does St Albans Water Dept serve?

St Albans Water Dept reports serving 10,200 people in Vermont, per its EPA record.

Has St Albans Water Dept had any water quality violations?

The EPA has 58 violations on file for St Albans Water Dept, of which 11 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.