Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2005-11-01 → 2005-11-30 |
| MCL | Health-based | Resolved | 2005-11-01 → 2005-11-30 |
| MCL | Health-based | Resolved | 2005-11-01 → 2005-11-30 |
| MCL | Health-based | Resolved | 2002-09-01 → 2002-09-30 |
| MCL | Health-based | Resolved | 2002-09-01 → 2002-09-30 |
| MCL | Health-based | Resolved | 2002-09-01 → 2002-09-30 |
| MCL | Health-based | Resolved | 2002-09-01 → 2002-09-30 |
| MCL | Health-based | Resolved | 2002-07-01 → 2002-07-31 |
| MCL | Health-based | Resolved | 2002-07-01 → 2002-07-31 |
| MCL | Health-based | Resolved | 2002-07-01 → 2002-07-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 432.45 µg/L 33% of the EPA limit 1300 µg/L
worst single sample: 939 µg/L | 172/201 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 3042.5 µg/L 30% of the EPA limit 10000 µg/L
worst single sample: 3430 µg/L | 116/140 | SYR4 | 2012–2019 |
| Lead | 11.765 µg/L 78% of the EPA limit 15 µg/L
worst single sample: 104 µg/L | 43/201 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.175 µg/L No EPA limit set
worst single sample: 3.8 µg/L | 26/61 | SYR4 | 2012–2019 |
| Chloroform | 18.8 µg/L No EPA limit set
worst single sample: 20 µg/L | 24/61 | SYR4 | 2012–2019 |
| Fluoride | 1412 µg/L 35% of the EPA limit 4000 µg/L
worst single sample: 1540 µg/L | 24/27 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 6.27 pCi/L No EPA limit set
worst single sample: 9.1 pCi/L | 22/22 | SYR4 | 2012–2019 |
| Bromodichloromethane | 4.815 µg/L No EPA limit set
worst single sample: 5.1 µg/L | 20/61 | SYR4 | 2012–2019 |
| Lead | 0.0034 mg/L 23% of the EPA limit 0.0150 mg/L | 19/19 | LCR | 2024 |
| Combined Radium (-226 And -228) | 2.72 pCi/L 54% of the EPA limit 5 pCi/L
worst single sample: 3.6 pCi/L | 17/18 | SYR4 | 2012–2019 |
| Bromoform | 1.8 µg/L No EPA limit set | 11/61 | SYR4 | 2012–2019 |
| TTHM | 26.5 µg/L 33% of the EPA limit 80 µg/L
worst single sample: 28 µg/L | 11/11 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 21.3 µg/L 36% of the EPA limit 60 µg/L
worst single sample: 24 µg/L | 10/11 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 12.4 µg/L No EPA limit set
worst single sample: 14 µg/L | 9/11 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 7.56 µg/L No EPA limit set
worst single sample: 8.6 µg/L | 9/11 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.575 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 6/11 | SYR4 | 2012–2019 |
| Lithium | 14.5 µg/L No EPA limit set | 5/8 | UCMR-5 | 2025 |
| 1,2-Dichloroethane | 0.9850 µg/L 20% of the EPA limit 5 µg/L
worst single sample: 1 µg/L | 2/73 | SYR4 | 2012–2019 |
| Barium | 11 µg/L 0.5% of the EPA limit 2000 µg/L | 1/26 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 1.4 µg/L No EPA limit set | 1/11 | SYR4 | 2012–2019 |
81 contaminants tested, none detected
Utility contact
Frequently asked questions about Round Hill, Town of
Is Round Hill, Town of tap water safe to drink?
EPA monitoring detected 25 contaminants in Round Hill, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Round Hill, Town of's water?
EPA monitoring detected Copper, Nitrate-Nitrite, Lead, Dibromochloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Round Hill, Town of serve?
Round Hill, Town of reports serving 5,055 people in Virginia, per its EPA record.
Has Round Hill, Town of had any water quality violations?
The EPA has 45 violations on file for Round Hill, Town of, of which 22 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.