Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2013-04-01 → 2013-06-30 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Resolved | 2009-10-01 → 2009-12-31 |
| MCL | Health-based | Archived | 1993-10-01 → 1993-10-31 |
| MCL | Health-based | Archived | 1993-10-01 → 1993-10-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 772.4 µg/L 59% of the EPA limit 1300 µg/L
worst single sample: 1080 µg/L | 69/80 | SYR4 | 2012–2018 |
| Dibromochloromethane | 6.1 µg/L No EPA limit set
worst single sample: 6.9 µg/L | 41/51 | SYR4 | 2012–2019 |
| Bromodichloromethane | 3.59 µg/L No EPA limit set
worst single sample: 7.9 µg/L | 39/51 | SYR4 | 2012–2019 |
| Bromoform | 5.85 µg/L No EPA limit set
worst single sample: 9.2 µg/L | 31/51 | SYR4 | 2012–2019 |
| Chloroform | 5.27 µg/L No EPA limit set
worst single sample: 8.8 µg/L | 30/51 | SYR4 | 2012–2019 |
| Trichloroethylene | 5.9 µg/L 118% of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 6 µg/L | 29/53 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 18.205 pCi/L No EPA limit set
worst single sample: 22.6 pCi/L | 22/22 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 1556.5 µg/L 16% of the EPA limit 10000 µg/L
worst single sample: 1560 µg/L | 22/62 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 7.225 pCi/L 144% of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 8.5 pCi/L | 18/18 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2024 |
| Barium | 106.2 µg/L 5.3% of the EPA limit 2000 µg/L
worst single sample: 108 µg/L | 10/10 | SYR4 | 2014–2018 |
| TTHM | 25.2 µg/L 32% of the EPA limit 80 µg/L
worst single sample: 26 µg/L | 9/9 | SYR4 | 2013–2019 |
| Lead | 51.06 µg/L 340% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 68 µg/L | 8/80 | SYR4 | 2012–2018 |
| cis-1,2-Dichloroethylene | 0.7000 µg/L 1% of the EPA limit 70 µg/L | 6/53 | SYR4 | 2012–2019 |
| Fluoride | 284 µg/L 7.1% of the EPA limit 4000 µg/L
worst single sample: 290 µg/L | 5/10 | SYR4 | 2014–2018 |
| Tetrachloroethylene | 2.26 µg/L 45% of the EPA limit 5 µg/L
worst single sample: 2.3 µg/L | 5/53 | SYR4 | 2012–2019 |
| trans-1,2-Dichloroethylene | 0.7800 µg/L 0.8% of the EPA limit 100 µg/L
worst single sample: 0.8000 µg/L | 5/53 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 2.125 µg/L 3.5% of the EPA limit 60 µg/L
worst single sample: 2.2 µg/L | 4/9 | SYR4 | 2013–2019 |
| Xylenes, Total | 3.155 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 3.2 µg/L | 4/53 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1 µg/L No EPA limit set | 2/9 | SYR4 | 2013–2019 |
| Ethylbenzene | 0.8900 µg/L 0.1% of the EPA limit 700 µg/L
worst single sample: 0.9000 µg/L | 2/53 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 1.685 µg/L No EPA limit set
worst single sample: 1.7 µg/L | 2/9 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 1.2 µg/L No EPA limit set | 1/9 | SYR4 | 2013–2019 |
| Vinyl Chloride | 1.1 µg/L 55% of the EPA limit 2 µg/L | 1/53 | SYR4 | 2012–2019 |
25 contaminants tested, none detected
Utility contact
Frequently asked questions about Marshall Waterworks
Is Marshall Waterworks tap water safe to drink?
EPA monitoring detected 24 contaminants in Marshall Waterworks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Marshall Waterworks's water?
EPA monitoring detected Copper, Dibromochloromethane, Bromodichloromethane, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Marshall Waterworks serve?
Marshall Waterworks reports serving 2,363 people in Virginia, per its EPA record.
Has Marshall Waterworks had any water quality violations?
The EPA has 103 violations on file for Marshall Waterworks, of which 11 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.