← Virginia

Tap water quality report

North River Park

EPA monitoring tested this supplier for 49 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

49
contaminants tested
12
detected
53
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Mathews

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
18
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1999-06-01 → 1999-06-30
MCL Health-based Archived 1999-06-01 → 1999-06-30
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2011-08-01 → 2011-08-31
MR Monitoring Resolved 2010-07-01 → 2010-07-31
MR Monitoring Resolved 2010-07-01 → 2010-07-31
MR Monitoring Resolved 2010-07-01 → 2010-07-31
MR Monitoring Resolved 2010-07-01 → 2010-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0104 mg/L 69%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Bromodichloromethane
3.085 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
4/5 SYR4 2013–2019
Chloroform
5.075 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
4/5 SYR4 2013–2019
Dibromochloromethane
1.985 µg/L
No EPA limit set
worst single sample: 2 µg/L
4/5 SYR4 2013–2019
Lead
8.054 µg/L 54%
of the EPA limit 15 µg/L
worst single sample: 8.75 µg/L
4/12 SYR4 2014–2017
Dichloroacetic Acid
8.17 µg/L
No EPA limit set
worst single sample: 8.9 µg/L
3/4 SYR4 2013–2019
TTHM
9.86 µg/L 12%
of the EPA limit 80 µg/L
worst single sample: 10 µg/L
3/3 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
10.22 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 11 µg/L
3/4 SYR4 2013–2019
Trichloroacetic Acid
1.78 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
3/4 SYR4 2013–2019
Combined Radium (-226 And -228)
0.2000 pCi/L 4%
of the EPA limit 5 pCi/L
1/1 SYR4 2019
Fluoride
210 µg/L 5.3%
of the EPA limit 4000 µg/L
1/2 SYR4 2014–2017
Gross Beta Particle Activity
2.2 pCi/L
No EPA limit set
1/2 SYR4 2013–2019
37 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBariumBenzeneBeryllium, TotalBromoformChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidEthylbenzeneMercuryMonobromoacetic AcidMonochloroacetic AcidNitrate-NitriteSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
STEVENS, ASHLEY
Phone
804-815-8603
Email
[email protected]

Frequently asked questions about North River Park

Is North River Park tap water safe to drink?

EPA monitoring detected 12 contaminants in North River Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in North River Park's water?

EPA monitoring detected Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does North River Park serve?

North River Park reports serving 53 people in Virginia, per its EPA record.

Has North River Park had any water quality violations?

The EPA has 18 violations on file for North River Park, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.