Tap water quality report

Massanutten Village

EPA monitoring tested this supplier for 85 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

85
contaminants tested
15
detected
5,472
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Rockingham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
32
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2005-10-01 → 2005-10-31
MCL Health-based Resolved 2005-10-01 → 2005-10-31
MCL Health-based Resolved 2005-10-01 → 2005-10-31
MCL Health-based Resolved 2005-10-01 → 2005-10-31
MR Monitoring Resolved 2020-10-01
MR Monitoring Resolved 2020-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
613 µg/L 47%
of the EPA limit 1300 µg/L
worst single sample: 680 µg/L
41/43 SYR4 2013–2019
Lead
0.0023 mg/L 16%
of the EPA limit 0.0150 mg/L
17/17 LCR 2024
Bromodichloromethane
5.9 µg/L
No EPA limit set
worst single sample: 6.8 µg/L
10/11 SYR4 2013–2019
Chloroform
11.615 µg/L
No EPA limit set
worst single sample: 14 µg/L
10/11 SYR4 2013–2019
Dibromochloromethane
3.08 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
9/11 SYR4 2013–2019
Dichloroacetic Acid
4.395 µg/L
No EPA limit set
worst single sample: 4.5 µg/L
8/8 SYR4 2013–2019
TTHM
21.85 µg/L 27%
of the EPA limit 80 µg/L
worst single sample: 25 µg/L
8/8 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
5.825 µg/L 9.7%
of the EPA limit 60 µg/L
worst single sample: 6 µg/L
8/8 SYR4 2013–2019
Barium
153.9 µg/L 7.7%
of the EPA limit 2000 µg/L
worst single sample: 159 µg/L
3/3 SYR4 2013–2019
Trichloroacetic Acid
1.48 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
3/8 SYR4 2013–2019
Lead
2.106 µg/L 14%
of the EPA limit 15 µg/L
worst single sample: 2.11 µg/L
2/43 SYR4 2013–2019
Lithium
20.1 µg/L
No EPA limit set
2/2 UCMR-5 2025
Bromoform
0.6000 µg/L
No EPA limit set
1/11 SYR4 2013–2019
Combined Radium (-226 And -228)
0.8000 pCi/L 16%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Gross Beta Particle Activity
1 pCi/L
No EPA limit set
1/1 SYR4 2016
70 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDalaponDibromoacetic AcidDinosebEthylbenzeneFluorideHfpo-DaMercuryMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitrate-NitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Frequently asked questions about Massanutten Village

Is Massanutten Village tap water safe to drink?

EPA monitoring detected 15 contaminants in Massanutten Village's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Massanutten Village's water?

EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Massanutten Village serve?

Massanutten Village reports serving 5,472 people, per its EPA record.

Has Massanutten Village had any water quality violations?

The EPA has 32 violations on file for Massanutten Village, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.