← Virginia

Tap water quality report

Shenandoah Utility Services

EPA monitoring tested this supplier for 49 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

49
contaminants tested
15
detected
55
people served
25
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Page

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

25
health-based violations
2,222
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2008-11-13
TT Health-based Resolved 2008-11-13
TT Health-based Resolved 2008-11-13
TT Health-based Resolved 2008-11-13
TT Health-based Resolved 2006-10-13
TT Health-based Resolved 2006-10-13
TT Health-based Resolved 2006-10-13
MCL Health-based Archived 2001-08-01 → 2001-08-31
MCL Health-based Archived 2001-08-01 → 2001-08-31
MCL Health-based Archived 1997-04-01 → 1997-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Nitrate-Nitrite
1890 µg/L 19%
of the EPA limit 10000 µg/L
14/18 SYR4 2013–2019
Copper
58.8 µg/L 4.5%
of the EPA limit 1300 µg/L
worst single sample: 59.5 µg/L
6/17 SYR4 2012–2018
Dibromochloromethane
0.9800 µg/L
No EPA limit set
worst single sample: 1 µg/L
5/9 SYR4 2013–2019
Bromodichloromethane
8.35 µg/L
No EPA limit set
worst single sample: 9.7 µg/L
4/9 SYR4 2013–2019
TTHM
2.425 µg/L 3%
of the EPA limit 80 µg/L
worst single sample: 2.5 µg/L
4/5 SYR4 2013–2017
Chloroform
64.15 µg/L
No EPA limit set
worst single sample: 71 µg/L
3/9 SYR4 2013–2019
Barium
15.7 µg/L 0.8%
of the EPA limit 2000 µg/L
worst single sample: 16 µg/L
2/2 SYR4 2014–2017
Gross Beta Particle Activity
1.59 pCi/L
No EPA limit set
worst single sample: 1.6 pCi/L
2/7 SYR4 2012–2014
Bromoform
1.1 µg/L
No EPA limit set
1/9 SYR4 2013–2019
Combined Radium (-226 And -228)
0.6000 pCi/L 12%
of the EPA limit 5 pCi/L
1/1 SYR4 2012
Dichloroacetic Acid
7.9 µg/L
No EPA limit set
1/5 SYR4 2013–2017
Fluoride
780 µg/L 20%
of the EPA limit 4000 µg/L
1/2 SYR4 2014–2017
Lead
5.18 µg/L 35%
of the EPA limit 15 µg/L
1/17 SYR4 2012–2018
Total Haloacetic Acids (HAA5)
7.9 µg/L 13%
of the EPA limit 60 µg/L
1/5 SYR4 2013–2017
34 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidEthylbenzeneMercuryMonobromoacetic AcidMonochloroacetic AcidSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MATHEWS, DAVID
Phone
540-743-5006
Email
[email protected]

Frequently asked questions about Shenandoah Utility Services

Is Shenandoah Utility Services tap water safe to drink?

EPA monitoring detected 15 contaminants in Shenandoah Utility Services's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Shenandoah Utility Services's water?

EPA monitoring detected Lead, Nitrate-Nitrite, Copper, Dibromochloromethane, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Shenandoah Utility Services serve?

Shenandoah Utility Services reports serving 55 people in Virginia, per its EPA record.

Has Shenandoah Utility Services had any water quality violations?

The EPA has 2222 violations on file for Shenandoah Utility Services, of which 25 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.