Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 83.32 µg/L 104% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 93.5 µg/L | 79/79 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 84.93 µg/L 142% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 113 µg/L | 79/79 | SYR4 | 2012–2019 |
| Copper | 24.42 µg/L 1.9% of the EPA limit 1300 µg/L
worst single sample: 33.3 µg/L | 17/23 | SYR4 | 2012–2019 |
| Lead | 0.00079 mg/L 5.3% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Nitrate-Nitrite | 110 µg/L 1.1% of the EPA limit 10000 µg/L | 14/16 | SYR4 | 2012–2019 |
| Lead | 4.135 µg/L 28% of the EPA limit 15 µg/L
worst single sample: 5.8 µg/L | 10/23 | SYR4 | 2012–2019 |
| Barium | 13.525 µg/L 0.7% of the EPA limit 2000 µg/L
worst single sample: 13.7 µg/L | 8/8 | SYR4 | 2012–2019 |
| Fluoride | 1511 µg/L 38% of the EPA limit 4000 µg/L
worst single sample: 1700 µg/L | 8/8 | SYR4 | 2012–2019 |
| Antimony, Total | 0.6800 µg/L 11% of the EPA limit 6 µg/L
worst single sample: 0.7000 µg/L | 3/8 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 0.6200 pCi/L 12% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2018 |
| Gross Alpha, Excl. Radon And U | 1.7 pCi/L 11% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2018 |
| Gross Beta Particle Activity | 1.4 pCi/L No EPA limit set | 1/1 | SYR4 | 2018 |
29 contaminants tested, none detected
Utility contact
Frequently asked questions about Ncsa - Schuyler
Is Ncsa - Schuyler tap water safe to drink?
EPA monitoring detected 12 contaminants in Ncsa - Schuyler's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Ncsa - Schuyler's water?
EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.
How many people does Ncsa - Schuyler serve?
Ncsa - Schuyler reports serving 480 people in Virginia, per its EPA record.
Has Ncsa - Schuyler had any water quality violations?
The EPA has 133 violations on file for Ncsa - Schuyler, of which 98 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.