Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2017-09-04 |
| TT | Health-based | Resolved | 2017-09-04 |
| TT | Health-based | Resolved | 2017-09-04 |
| RPT | Monitoring | Resolved | 2017-12-13 |
| RPT | Monitoring | Resolved | 2017-12-13 |
| RPT | Monitoring | Resolved | 2017-12-13 |
| MR | Monitoring | Resolved | 2017-09-01 → 2017-09-30 |
| MR | Monitoring | Resolved | 2017-09-01 → 2017-09-30 |
| MR | Monitoring | Resolved | 2017-09-01 → 2017-09-30 |
| MR | Monitoring | Resolved | 2017-08-01 → 2017-08-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 424.9 µg/L 33% of the EPA limit 1300 µg/L
worst single sample: 1370 µg/L | 198/203 | SYR4 | 2012–2019 |
| Lead | 29.1 µg/L 194% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 57.1 µg/L | 167/202 | SYR4 | 2012–2019 |
| TTHM | 38.3 µg/L 48% of the EPA limit 80 µg/L
worst single sample: 79.6 µg/L | 68/86 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.1 µg/L No EPA limit set
worst single sample: 16.2 µg/L | 66/84 | SYR4 | 2012–2019 |
| Chloroform | 25.34 µg/L No EPA limit set
worst single sample: 59.1 µg/L | 64/84 | SYR4 | 2012–2019 |
| Dibromochloromethane | 4.69 µg/L No EPA limit set
worst single sample: 6.8 µg/L | 63/84 | SYR4 | 2012–2019 |
| Nitrate | 1300 µg/L 13% of the EPA limit 10000 µg/L | 56/56 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 18.045 µg/L 30% of the EPA limit 60 µg/L
worst single sample: 34.8 µg/L | 40/88 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 10.025 µg/L No EPA limit set
worst single sample: 14.1 µg/L | 40/83 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 9.55 µg/L No EPA limit set
worst single sample: 20.7 µg/L | 39/83 | SYR4 | 2012–2019 |
| Lead | 0.0017 mg/L 11% of the EPA limit 0.0150 mg/L | 27/27 | LCR | 2025 |
| Bromoform | 1.8 µg/L No EPA limit set
worst single sample: 2.5 µg/L | 23/84 | SYR4 | 2012–2019 |
| Barium | 280 µg/L 14% of the EPA limit 2000 µg/L
worst single sample: 309 µg/L | 11/11 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 1.55 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 11/83 | SYR4 | 2012–2019 |
| Selenium | 0.9500 µg/L 1.9% of the EPA limit 50 µg/L
worst single sample: 1 µg/L | 11/11 | SYR4 | 2013–2019 |
| Lithium | 31.6 µg/L No EPA limit set | 11/12 | UCMR-5 | 2024 |
| Arsenic | 2.105 µg/L 21% of the EPA limit 10 µg/L
worst single sample: 2.6 µg/L | 10/11 | SYR4 | 2013–2019 |
| Fluoride | 200 µg/L 5% of the EPA limit 4000 µg/L | 8/11 | SYR4 | 2013–2019 |
| Gross Beta Particle Activity | 6.175 pCi/L No EPA limit set
worst single sample: 7.1 pCi/L | 6/8 | SYR4 | 2014–2019 |
| Gross Alpha, Excl. Radon And U | 5.015 pCi/L 33% of the EPA limit 15 pCi/L
worst single sample: 5.3 pCi/L | 4/9 | SYR4 | 2014–2019 |
| Cyanide | 2 µg/L 1% of the EPA limit 200 µg/L | 2/11 | SYR4 | 2013–2019 |
| Chromium | 5 µg/L 5% of the EPA limit 100 µg/L | 1/11 | SYR4 | 2013–2019 |
| Combined Radium (-226 And -228) | 0.5600 pCi/L 11% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
82 contaminants tested, none detected
Utility contact
Frequently asked questions about Roy City Water
Is Roy City Water tap water safe to drink?
EPA monitoring detected 23 contaminants in Roy City Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Roy City Water's water?
EPA monitoring detected Copper, Lead, TTHM, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Roy City Water serve?
Roy City Water reports serving 38,800 people in Utah, per its EPA record.
Has Roy City Water had any water quality violations?
The EPA has 422 violations on file for Roy City Water, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.