← Utah

Tap water quality report

Wolf Creek Water and Sewer Id

EPA monitoring tested this supplier for 62 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

62
contaminants tested
12
detected
1,345
people served
38
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Weber

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

38
health-based violations
343
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-10-01 → 2014-10-31
MCL Health-based Resolved 2014-10-01 → 2014-10-31
MCL Health-based Resolved 2014-10-01 → 2014-10-31
MCL Health-based Archived 2013-07-01 → 2013-07-31
MCL Health-based Archived 2013-07-01 → 2013-07-31
TT Health-based Resolved 2010-04-02
TT Health-based Resolved 2010-04-02
TT Health-based Resolved 2010-04-02
TT Health-based Resolved 2010-04-02
TT Health-based Resolved 2010-04-02

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
324 µg/L 3.2%
of the EPA limit 10000 µg/L
worst single sample: 2590 µg/L
48/56 SYR4 2012–2019
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Copper
659.454 µg/L 51%
of the EPA limit 1300 µg/L
worst single sample: 724.625 µg/L
10/10 SYR4 2014–2017
Barium
188.6 µg/L 9.4%
of the EPA limit 2000 µg/L
worst single sample: 199 µg/L
9/9 SYR4 2013–2019
Lead
15.0612 µg/L 100%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18.158 µg/L
8/10 SYR4 2014–2017
Arsenic
14.71 µg/L 147%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 15.7 µg/L
7/9 SYR4 2013–2019
Fluoride
593.525 µg/L 15%
of the EPA limit 4000 µg/L
worst single sample: 600 µg/L
6/9 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
2.935 pCi/L 20%
of the EPA limit 15 pCi/L
worst single sample: 3.1 pCi/L
4/6 SYR4 2013–2016
Gross Beta Particle Activity
7.98 pCi/L
No EPA limit set
worst single sample: 8.3 pCi/L
3/6 SYR4 2013–2016
Selenium
0.5000 µg/L 1%
of the EPA limit 50 µg/L
2/10 SYR4 2013–2019
Cadmium
0.4000 µg/L 8%
of the EPA limit 5 µg/L
1/10 SYR4 2013–2019
Thallium, Total
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/10 SYR4 2013–2019
50 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
THOMAS, ROBERT LYNN
Phone
801-745-3435
Email
[email protected]

Frequently asked questions about Wolf Creek Water and Sewer Id

Is Wolf Creek Water and Sewer Id tap water safe to drink?

EPA monitoring detected 12 contaminants in Wolf Creek Water and Sewer Id's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wolf Creek Water and Sewer Id's water?

EPA monitoring detected Nitrate, Lead, Copper, Barium, Lead, and others. The full list with the level and data source for each is above.

How many people does Wolf Creek Water and Sewer Id serve?

Wolf Creek Water and Sewer Id reports serving 1,345 people in Utah, per its EPA record.

Has Wolf Creek Water and Sewer Id had any water quality violations?

The EPA has 343 violations on file for Wolf Creek Water and Sewer Id, of which 38 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.