← Utah

Tap water quality report

Goshen Town Water

EPA monitoring tested this supplier for 75 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
16
detected
925
people served
15
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Utah

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

15
health-based violations
276
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2017-03-17
TT Health-based Resolved 2017-03-17
TT Health-based Resolved 2017-03-17
MCL Health-based Resolved 2015-09-01 → 2015-09-30
MCL Health-based Resolved 2015-09-01 → 2015-09-30
MCL Health-based Resolved 2015-09-01 → 2015-09-30
MCL Health-based Resolved 2015-09-01 → 2015-09-30
MCL Health-based Resolved 2015-08-01 → 2015-08-31
MCL Health-based Resolved 2015-08-01 → 2015-08-31
MCL Health-based Resolved 2015-08-01 → 2015-08-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1049 µg/L 10%
of the EPA limit 10000 µg/L
worst single sample: 1060 µg/L
32/38 SYR4 2012–2019
Copper
383.31 µg/L 29%
of the EPA limit 1300 µg/L
worst single sample: 544 µg/L
22/22 SYR4 2016–2019
Lead
0.0077 mg/L 51%
of the EPA limit 0.0150 mg/L
16/16 LCR 2016
Lead
8.15 µg/L 54%
of the EPA limit 15 µg/L
worst single sample: 8.2 µg/L
11/22 SYR4 2016–2019
Arsenic
6.525 µg/L 65%
of the EPA limit 10 µg/L
worst single sample: 6.6 µg/L
6/6 SYR4 2013–2019
Barium
127 µg/L 6.4%
of the EPA limit 2000 µg/L
5/5 SYR4 2013–2019
Fluoride
323.28 µg/L 8.1%
of the EPA limit 4000 µg/L
worst single sample: 329.1 µg/L
5/5 SYR4 2013–2019
Selenium
5.2 µg/L 10%
of the EPA limit 50 µg/L
5/5 SYR4 2013–2019
TTHM
2 µg/L 2.5%
of the EPA limit 80 µg/L
worst single sample: 2.1 µg/L
5/10 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
6.89 pCi/L 46%
of the EPA limit 15 pCi/L
worst single sample: 7.1 pCi/L
3/3 SYR4 2016–2019
Gross Beta Particle Activity
26.2 pCi/L
No EPA limit set
worst single sample: 27 pCi/L
3/3 SYR4 2016–2019
Thallium, Total
0.2000 µg/L 10%
of the EPA limit 2 µg/L
2/5 SYR4 2013–2019
Bromoform
1.5 µg/L
No EPA limit set
1/4 SYR4 2013–2019
Combined Radium (-226 And -228)
0.2000 pCi/L 4%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Dibromochloromethane
0.6000 µg/L
No EPA limit set
1/4 SYR4 2013–2019
Nitrate-Nitrite
1000 µg/L 10%
of the EPA limit 10000 µg/L
1/1 SYR4 2013
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PENA, RACHEL
Phone
801-667-9910
Email
[email protected]

Frequently asked questions about Goshen Town Water

Is Goshen Town Water tap water safe to drink?

EPA monitoring detected 16 contaminants in Goshen Town Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Goshen Town Water's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Goshen Town Water serve?

Goshen Town Water reports serving 925 people in Utah, per its EPA record.

Has Goshen Town Water had any water quality violations?

The EPA has 276 violations on file for Goshen Town Water, of which 15 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.