← Utah

Tap water quality report

Cedar Fort Water

EPA monitoring tested this supplier for 74 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
18
detected
400
people served
6
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Utah

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
990
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2019-10-01
TT Health-based Resolved 2019-10-01
TT Health-based Resolved 2019-10-01
TT Health-based Resolved 2017-03-10
TT Health-based Resolved 2017-03-10
TT Health-based Resolved 2017-03-10
RPT Monitoring Resolved 2025-07-02
RPT Monitoring Resolved 2025-07-02
RPT Monitoring Resolved 2025-07-02
Other Monitoring Resolved 2025-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0060 mg/L 40%
of the EPA limit 0.0150 mg/L
21/21 LCR 2026
Nitrate
1100 µg/L 11%
of the EPA limit 10000 µg/L
18/36 SYR4 2012–2019
Fluoride
2586.36 µg/L 65%
of the EPA limit 4000 µg/L
worst single sample: 2600 µg/L
10/14 SYR4 2012–2019
Copper
167.6 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 178 µg/L
9/10 SYR4 2013–2016
Gross Beta Particle Activity
5.8 pCi/L
No EPA limit set
worst single sample: 6.4 pCi/L
9/10 SYR4 2012–2019
Lead
5.82 µg/L 39%
of the EPA limit 15 µg/L
worst single sample: 6.1 µg/L
9/10 SYR4 2013–2016
Gross Alpha, Excl. Radon And U
8.69 pCi/L 58%
of the EPA limit 15 pCi/L
worst single sample: 8.9 pCi/L
8/10 SYR4 2012–2019
Barium
374.51 µg/L 19%
of the EPA limit 2000 µg/L
worst single sample: 494.3 µg/L
7/7 SYR4 2013–2019
Combined Radium (-226 And -228)
3.075 pCi/L 62%
of the EPA limit 5 pCi/L
worst single sample: 3.1 pCi/L
6/6 SYR4 2012–2019
Selenium
1.555 µg/L 3.1%
of the EPA limit 50 µg/L
worst single sample: 1.6 µg/L
4/7 SYR4 2013–2019
Arsenic
8.26 µg/L 83%
of the EPA limit 10 µg/L
worst single sample: 8.4 µg/L
3/7 SYR4 2013–2019
Bromodichloromethane
2.29 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
3/4 SYR4 2012–2019
Dibromochloromethane
2.13 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
3/4 SYR4 2012–2019
TTHM
7.15 µg/L 8.9%
of the EPA limit 80 µg/L
worst single sample: 7.5 µg/L
3/3 SYR4 2012–2019
Cyanide
4.9 µg/L 2.5%
of the EPA limit 200 µg/L
worst single sample: 5 µg/L
2/7 SYR4 2013–2019
Chloroform
2.79 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
2/4 SYR4 2012–2019
Bromoform
0.5000 µg/L
No EPA limit set
1/4 SYR4 2012–2019
Dibromoacetic Acid
1.4 µg/L
No EPA limit set
1/3 SYR4 2012–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
COOK, WYATT
Phone
801-768-2147
Email
[email protected]

Frequently asked questions about Cedar Fort Water

Is Cedar Fort Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Cedar Fort Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cedar Fort Water's water?

EPA monitoring detected Lead, Nitrate, Fluoride, Copper, Gross Beta Particle Activity, and others. The full list with the level and data source for each is above.

How many people does Cedar Fort Water serve?

Cedar Fort Water reports serving 400 people in Utah, per its EPA record.

Has Cedar Fort Water had any water quality violations?

The EPA has 990 violations on file for Cedar Fort Water, of which 6 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.