← Utah

Tap water quality report

Trenton Town Water

EPA monitoring tested this supplier for 76 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
20
detected
490
people served
16
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Cache

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

16
health-based violations
662
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
9000 µg/L 90%
of the EPA limit 10000 µg/L
worst single sample: 10400 µg/L
94/96 SYR4 2012–2019
Lead
0.0160 mg/L 107%
above the EPA limit of 0.0150 mg/L
21/21 LCR 2025
Dibromochloromethane
2.8 µg/L
No EPA limit set
18/26 SYR4 2012–2019
TTHM
11 µg/L 14%
of the EPA limit 80 µg/L
worst single sample: 14.4 µg/L
18/24 SYR4 2012–2019
Bromodichloromethane
3.74 µg/L
No EPA limit set
worst single sample: 4.7 µg/L
17/26 SYR4 2012–2019
Copper
112 µg/L 8.6%
of the EPA limit 1300 µg/L
worst single sample: 147 µg/L
11/14 SYR4 2014–2017
Lead
2.62 µg/L 17%
of the EPA limit 15 µg/L
worst single sample: 2.7 µg/L
9/15 SYR4 2014–2018
Nitrate-Nitrite
5040 µg/L 50%
of the EPA limit 10000 µg/L
worst single sample: 6300 µg/L
8/8 SYR4 2012–2017
Arsenic
1.97 µg/L 20%
of the EPA limit 10 µg/L
worst single sample: 2 µg/L
7/7 SYR4 2013–2018
Barium
66.1 µg/L 3.3%
of the EPA limit 2000 µg/L
worst single sample: 67 µg/L
7/7 SYR4 2013–2018
Chloroform
5.9 µg/L
No EPA limit set
worst single sample: 6.4 µg/L
6/26 SYR4 2012–2019
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
5/7 SYR4 2013–2018
Gross Alpha, Excl. Radon And U
1.055 pCi/L 7%
of the EPA limit 15 pCi/L
worst single sample: 1.1 pCi/L
4/5 SYR4 2013–2017
Selenium
0.7850 µg/L 1.6%
of the EPA limit 50 µg/L
worst single sample: 0.8000 µg/L
4/7 SYR4 2013–2018
Bromoform
1.25 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
3/26 SYR4 2012–2019
Dichloroacetic Acid
2.83 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
2/24 SYR4 2012–2019
Cyanide
3 µg/L 1.5%
of the EPA limit 200 µg/L
1/7 SYR4 2013–2018
Gross Beta Particle Activity
0.8900 pCi/L
No EPA limit set
1/1 SYR4 2018
Total Haloacetic Acids (HAA5)
2.9 µg/L 4.8%
of the EPA limit 60 µg/L
1/24 SYR4 2012–2019
Trichloroacetic Acid
1.5 µg/L
No EPA limit set
1/24 SYR4 2012–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOHN, KACEE JO
Phone
435-563-9929
Email
[email protected]

Frequently asked questions about Trenton Town Water

Is Trenton Town Water tap water safe to drink?

EPA monitoring detected 20 contaminants in Trenton Town Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Trenton Town Water's water?

EPA monitoring detected Nitrate, Lead, Dibromochloromethane, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Trenton Town Water serve?

Trenton Town Water reports serving 490 people in Utah, per its EPA record.

Has Trenton Town Water had any water quality violations?

The EPA has 662 violations on file for Trenton Town Water, of which 16 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.