← Utah

Tap water quality report

Acme Water Company

EPA monitoring tested this supplier for 76 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
14
detected
880
people served
17
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Box Elder

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

17
health-based violations
238
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1995-06-01 → 1995-06-30
MCL Health-based Archived 1995-04-01 → 1995-04-30
MCL Health-based Archived 1994-05-01 → 1994-05-31
MCL Health-based Archived 1993-11-01 → 1993-11-30
MCL Health-based Archived 1993-11-01 → 1993-11-30
MCL Health-based Archived 1993-11-01 → 1993-11-30
MCL Health-based Archived 1993-10-01 → 1993-10-31
MCL Health-based Archived 1993-10-01 → 1993-10-31
MCL Health-based Archived 1993-07-01 → 1993-07-31
MCL Health-based Archived 1993-07-01 → 1993-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
600.44 µg/L 6%
of the EPA limit 10000 µg/L
worst single sample: 608.8 µg/L
40/40 SYR4 2012–2019
Copper
67.875 µg/L 5.2%
of the EPA limit 1300 µg/L
worst single sample: 82.6 µg/L
20/20 SYR4 2014–2017
Lead
0.0048 mg/L 32%
of the EPA limit 0.0150 mg/L
18/18 LCR 2026
Lead
5.46 µg/L 36%
of the EPA limit 15 µg/L
worst single sample: 6.9 µg/L
9/20 SYR4 2014–2017
Barium
106.04 µg/L 5.3%
of the EPA limit 2000 µg/L
worst single sample: 119.9 µg/L
5/5 SYR4 2016–2019
Selenium
0.7800 µg/L 1.6%
of the EPA limit 50 µg/L
worst single sample: 0.8000 µg/L
5/5 SYR4 2016–2019
Arsenic
0.5950 µg/L 5.9%
of the EPA limit 10 µg/L
worst single sample: 0.6000 µg/L
2/5 SYR4 2016–2019
Dibromochloromethane
0.6950 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
2/4 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
0.6645 pCi/L 4.4%
of the EPA limit 15 pCi/L
worst single sample: 0.6800 pCi/L
2/7 SYR4 2015–2019
Nitrate-Nitrite
400 µg/L 4%
of the EPA limit 10000 µg/L
2/2 SYR4 2012
TTHM
1.74 µg/L 2.2%
of the EPA limit 80 µg/L
worst single sample: 1.8 µg/L
2/2 SYR4 2014–2017
Bromoform
1.1 µg/L
No EPA limit set
1/4 SYR4 2014–2019
Cyanide
8.8 µg/L 4.4%
of the EPA limit 200 µg/L
1/5 SYR4 2016–2019
Gross Beta Particle Activity
6.4 pCi/L
No EPA limit set
1/7 SYR4 2015–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MORRIS, KENDALL A
Phone
435-279-1044
Email
[email protected]

Frequently asked questions about Acme Water Company

Is Acme Water Company tap water safe to drink?

EPA monitoring detected 14 contaminants in Acme Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Acme Water Company's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Acme Water Company serve?

Acme Water Company reports serving 880 people in Utah, per its EPA record.

Has Acme Water Company had any water quality violations?

The EPA has 238 violations on file for Acme Water Company, of which 17 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.