← Texas

Tap water quality report

Sunko Wsc

EPA monitoring tested this supplier for 109 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
19
detected
5,064
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Wilson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
6
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2019-04-01 → 2019-06-30
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
260 µg/L 20%
of the EPA limit 1300 µg/L
worst single sample: 270 µg/L
38/42 SYR4 2014–2017
Nitrate
50 µg/L 0.5%
of the EPA limit 10000 µg/L
24/32 SYR4 2012–2019
Bromoform
14.11 µg/L
No EPA limit set
worst single sample: 16.2 µg/L
20/24 SYR4 2013–2019
Dibromochloromethane
11.89 µg/L
No EPA limit set
worst single sample: 15.5 µg/L
20/24 SYR4 2013–2019
Lead
0.0011 mg/L 7.2%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
TTHM
35.63 µg/L 45%
of the EPA limit 80 µg/L
worst single sample: 39.4 µg/L
14/14 SYR4 2013–2019
Bromodichloromethane
6.25 µg/L
No EPA limit set
worst single sample: 7.6 µg/L
11/24 SYR4 2013–2019
Lead
61.5 µg/L 410%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 89 µg/L
11/42 SYR4 2014–2017
Dibromoacetic Acid
3.065 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
8/14 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
4.425 µg/L 7.4%
of the EPA limit 60 µg/L
worst single sample: 4.6 µg/L
8/14 SYR4 2013–2019
Chloroform
2.2 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
6/24 SYR4 2013–2019
Dichloroacetic Acid
1.55 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
6/14 SYR4 2013–2019
Nitrate-Nitrite
44 µg/L 0.4%
of the EPA limit 10000 µg/L
worst single sample: 50 µg/L
5/6 SYR4 2012–2015
Barium
302.25 µg/L 15%
of the EPA limit 2000 µg/L
worst single sample: 309 µg/L
4/4 SYR4 2016–2019
Fluoride
407 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 410 µg/L
4/4 SYR4 2014–2017
Lithium
64.3 µg/L
No EPA limit set
4/4 UCMR-5 2024
Gross Beta Particle Activity
9.55 pCi/L
No EPA limit set
worst single sample: 9.6 pCi/L
3/3 SYR4 2012–2018
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
1/1 SYR4 2012
Xylenes, Total
1.1 µg/L 0%
of the EPA limit 10000 µg/L
1/10 SYR4 2015–2019
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DEAGEN, JOHNIE, R
Phone
830-745-2399
Email
[email protected]

Frequently asked questions about Sunko Wsc

Is Sunko Wsc tap water safe to drink?

EPA monitoring detected 19 contaminants in Sunko Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sunko Wsc's water?

EPA monitoring detected Copper, Nitrate, Bromoform, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does Sunko Wsc serve?

Sunko Wsc reports serving 5,064 people in Texas, per its EPA record.

Has Sunko Wsc had any water quality violations?

The EPA has 6 violations on file for Sunko Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.