Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Resolved | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Resolved | 2025-10-01 → 2025-12-31 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-07-01 → 2025-09-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 18.745 µg/L No EPA limit set
worst single sample: 28.8 µg/L | 40/40 | SYR4 | 2012–2019 |
| Bromoform | 40.485 µg/L No EPA limit set
worst single sample: 42.9 µg/L | 40/40 | SYR4 | 2012–2019 |
| Chloroform | 9.73 µg/L No EPA limit set
worst single sample: 13.2 µg/L | 40/40 | SYR4 | 2012–2019 |
| Dibromochloromethane | 39.32 µg/L No EPA limit set
worst single sample: 53.5 µg/L | 40/40 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 11.045 µg/L No EPA limit set
worst single sample: 16.4 µg/L | 32/32 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 4.325 µg/L No EPA limit set
worst single sample: 7.2 µg/L | 32/32 | SYR4 | 2012–2019 |
| TTHM | 100.565 µg/L 126% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 125 µg/L | 32/32 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 17.615 µg/L 29% of the EPA limit 60 µg/L
worst single sample: 30.8 µg/L | 32/32 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 3.6 µg/L No EPA limit set
worst single sample: 7.2 µg/L | 31/32 | SYR4 | 2012–2019 |
| Copper | 262.5 µg/L 20% of the EPA limit 1300 µg/L
worst single sample: 330 µg/L | 26/27 | SYR4 | 2012–2018 |
| Lead | 8 µg/L 53% of the EPA limit 15 µg/L
worst single sample: 12 µg/L | 17/27 | SYR4 | 2012–2018 |
| Nitrate | 50 µg/L 0.5% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 6/6 | LCR | 2024 |
| Barium | 33.4 µg/L 1.7% of the EPA limit 2000 µg/L
worst single sample: 34 µg/L | 3/3 | SYR4 | 2012–2018 |
| Fluoride | 1159 µg/L 29% of the EPA limit 4000 µg/L
worst single sample: 1160 µg/L | 3/3 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 49 µg/L 0.5% of the EPA limit 10000 µg/L
worst single sample: 50 µg/L | 3/3 | SYR4 | 2012–2015 |
| Xylenes, Total | 2.7 µg/L 0% of the EPA limit 10000 µg/L
worst single sample: 2.8 µg/L | 3/8 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 3.28 pCi/L 66% of the EPA limit 5 pCi/L
worst single sample: 3.4 pCi/L | 2/2 | SYR4 | 2012–2018 |
| Gross Beta Particle Activity | 6.035 pCi/L No EPA limit set
worst single sample: 6.1 pCi/L | 2/2 | SYR4 | 2012–2018 |
| Monobromoacetic Acid | 1.385 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 2/32 | SYR4 | 2012–2019 |
| Di(2-ethylhexyl) Phthalate | 1.2 µg/L 20% of the EPA limit 6 µg/L | 1/8 | SYR4 | 2012–2019 |
| Ethylbenzene | 0.6000 µg/L 0.1% of the EPA limit 700 µg/L | 1/8 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 3.4 pCi/L 23% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2018 |
| Selenium | 4.1 µg/L 8.2% of the EPA limit 50 µg/L | 1/3 | SYR4 | 2012–2018 |
55 contaminants tested, none detected
Utility contact
Frequently asked questions about Lake Livingston Heights Wsc
Is Lake Livingston Heights Wsc tap water safe to drink?
EPA monitoring detected 24 contaminants in Lake Livingston Heights Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Lake Livingston Heights Wsc's water?
EPA monitoring detected Bromodichloromethane, Bromoform, Chloroform, Dibromochloromethane, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Lake Livingston Heights Wsc serve?
Lake Livingston Heights Wsc reports serving 150 people in Texas, per its EPA record.
Has Lake Livingston Heights Wsc had any water quality violations?
The EPA has 183 violations on file for Lake Livingston Heights Wsc, of which 96 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.