← Texas

Tap water quality report

City of Point

EPA monitoring tested this supplier for 108 contaminants and detected 28. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
28
detected
3,600
people served
145
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Rains

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

145
health-based violations
865
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2023-05-01 → 2023-05-31
TT Health-based Resolved 2023-05-01 → 2023-05-31
TT Health-based Resolved 2023-05-01 → 2023-05-31
TT Health-based Resolved 2023-05-01 → 2023-05-31
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30
TT Health-based Resolved 2021-04-01 → 2021-04-30
TT Health-based Resolved 2021-04-01 → 2021-04-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0083 µg/L 1/1 2025
Pfhxa 0.0030 µg/L 1/1 2025
PFOS 0.0065 µg/L 1/1 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
60.6 µg/L
No EPA limit set
worst single sample: 90.4 µg/L
56/56 SYR4 2012–2019
Bromodichloromethane
11.67 µg/L
No EPA limit set
worst single sample: 20.2 µg/L
55/56 SYR4 2012–2019
Copper
226.4 µg/L 17%
of the EPA limit 1300 µg/L
worst single sample: 900 µg/L
54/107 SYR4 2012–2019
TTHM
70.87 µg/L 89%
of the EPA limit 80 µg/L
worst single sample: 103 µg/L
48/49 SYR4 2012–2019
Dichloroacetic Acid
29.54 µg/L
No EPA limit set
worst single sample: 53.2 µg/L
47/48 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
55.36 µg/L 92%
of the EPA limit 60 µg/L
worst single sample: 99 µg/L
47/48 SYR4 2012–2019
Trichloroacetic Acid
25.63 µg/L
No EPA limit set
worst single sample: 45.8 µg/L
47/48 SYR4 2012–2019
Monochloroacetic Acid
3.63 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
28/48 SYR4 2012–2019
Lead
21.05 µg/L 140%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 22 µg/L
20/107 SYR4 2012–2019
Nitrate
446 µg/L 4.5%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Dibromochloromethane
3.7 µg/L
No EPA limit set
17/56 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Monobromoacetic Acid
14.185 µg/L
No EPA limit set
worst single sample: 22.6 µg/L
10/48 SYR4 2012–2019
Barium
78.6 µg/L 3.9%
of the EPA limit 2000 µg/L
worst single sample: 80 µg/L
8/8 SYR4 2012–2019
Fluoride
222.6 µg/L 5.6%
of the EPA limit 4000 µg/L
worst single sample: 224 µg/L
8/8 SYR4 2012–2019
Chromium
3.298 µg/L 3.3%
of the EPA limit 100 µg/L
worst single sample: 3.6 µg/L
5/8 SYR4 2012–2019
Atrazine
0.3020 µg/L 10%
of the EPA limit 3 µg/L
worst single sample: 0.3200 µg/L
4/8 SYR4 2012–2019
Cyanide
145.6 µg/L 73%
of the EPA limit 200 µg/L
worst single sample: 148 µg/L
4/6 SYR4 2014–2019
Arsenic
1.544 µg/L 15%
of the EPA limit 10 µg/L
worst single sample: 1.6 µg/L
3/8 SYR4 2012–2019
Bromoform
23.56 µg/L
No EPA limit set
worst single sample: 24.7 µg/L
2/56 SYR4 2012–2019
Combined Radium (-226 And -228)
1.475 pCi/L 30%
of the EPA limit 5 pCi/L
worst single sample: 1.5 pCi/L
2/2 SYR4 2012–2018
Di(2-ethylhexyl) Phthalate
0.7000 µg/L 12%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Gross Beta Particle Activity
4.1 pCi/L
No EPA limit set
1/2 SYR4 2012–2018
Selenium
1.8 µg/L 3.6%
of the EPA limit 50 µg/L
1/8 SYR4 2012–2019
Thallium, Total
0.0080 µg/L 0.4%
of the EPA limit 2 µg/L
1/8 SYR4 2012–2019
80 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NELSON, ANGELA
Phone
903-598-3296
Email
[email protected]

Frequently asked questions about City of Point

Is City of Point tap water safe to drink?

EPA monitoring detected 28 contaminants in City of Point's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Point's water?

EPA monitoring detected Chloroform, Bromodichloromethane, Copper, TTHM, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does City of Point serve?

City of Point reports serving 3,600 people in Texas, per its EPA record.

Has City of Point had any water quality violations?

The EPA has 865 violations on file for City of Point, of which 145 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.