← Texas

Tap water quality report

Montgomery County Mud 18

EPA monitoring tested this supplier for 109 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
24
detected
7,608
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Montgomery

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
17
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2016-12-30
MR Monitoring Resolved 2016-12-30
Other Monitoring Resolved 2006-07-01
Other Monitoring Resolved 2006-06-01
Other Monitoring Resolved 2006-05-01
MR Monitoring Resolved 2006-03-01 → 2006-03-31
MR Monitoring Resolved 2006-03-01 → 2006-03-31
MR Monitoring Resolved 2006-03-01 → 2006-03-31
MR Monitoring Resolved 2006-03-01 → 2006-03-31
MR Monitoring Resolved 2006-02-01 → 2006-02-28

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
6:2 Fts 0.0056 µg/L 1/4 2023
Pfba 0.0116 µg/L 1/4 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
176.25 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 458 µg/L
116/124 SYR4 2012–2018
Nitrate
67.5 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 70 µg/L
26/32 SYR4 2012–2019
Lead
13.13 µg/L 88%
of the EPA limit 15 µg/L
worst single sample: 26 µg/L
19/124 SYR4 2012–2018
Dibromochloromethane
14.45 µg/L
No EPA limit set
worst single sample: 19 µg/L
14/15 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
14/14 LCR 2024
Bromodichloromethane
5.8 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
13/15 SYR4 2012–2019
Bromoform
27.58 µg/L
No EPA limit set
worst single sample: 31 µg/L
13/15 SYR4 2012–2019
TTHM
33.18 µg/L 41%
of the EPA limit 80 µg/L
worst single sample: 33.6 µg/L
7/7 SYR4 2013–2019
Chloroform
6.425 µg/L
No EPA limit set
worst single sample: 8 µg/L
6/15 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
7.05 µg/L 12%
of the EPA limit 60 µg/L
worst single sample: 7.9 µg/L
6/7 SYR4 2013–2019
Barium
111.66 µg/L 5.6%
of the EPA limit 2000 µg/L
worst single sample: 136 µg/L
5/5 SYR4 2012–2018
Dibromoacetic Acid
4.46 µg/L
No EPA limit set
worst single sample: 4.5 µg/L
5/7 SYR4 2013–2019
Fluoride
1046 µg/L 26%
of the EPA limit 4000 µg/L
worst single sample: 1050 µg/L
5/5 SYR4 2012–2018
Nitrate-Nitrite
65.5 µg/L 0.7%
of the EPA limit 10000 µg/L
worst single sample: 70 µg/L
4/6 SYR4 2012–2019
Lithium
52.3 µg/L
No EPA limit set
4/4 UCMR-5 2023
Selenium
3.675 µg/L 7.4%
of the EPA limit 50 µg/L
worst single sample: 3.7 µg/L
2/5 SYR4 2012–2018
Combined Radium (-226 And -228)
3 pCi/L 60%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Dichloroacetic Acid
1.3 µg/L
No EPA limit set
1/7 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
4.2 pCi/L 28%
of the EPA limit 15 pCi/L
1/3 SYR4 2015–2018
Gross Beta Particle Activity
7.5 pCi/L
No EPA limit set
1/4 SYR4 2012–2018
Monochloroacetic Acid
7.9 µg/L
No EPA limit set
1/7 SYR4 2013–2019
Xylenes, Total
0.6000 µg/L 0%
of the EPA limit 10000 µg/L
1/8 SYR4 2012–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MCFARLAND, SUSAN
Phone
713-951-0800
Email
[email protected]

Frequently asked questions about Montgomery County Mud 18

Is Montgomery County Mud 18 tap water safe to drink?

EPA monitoring detected 24 contaminants in Montgomery County Mud 18's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Montgomery County Mud 18's water?

EPA monitoring detected Copper, Nitrate, Lead, Dibromochloromethane, Lead, and others. The full list with the level and data source for each is above.

How many people does Montgomery County Mud 18 serve?

Montgomery County Mud 18 reports serving 7,608 people in Texas, per its EPA record.

Has Montgomery County Mud 18 had any water quality violations?

The EPA has 17 violations on file for Montgomery County Mud 18, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.