← Texas

Tap water quality report

City of Colorado City

EPA monitoring tested this supplier for 109 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
23
detected
3,991
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Mitchell

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
38
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2014-12-01
Other Monitoring Unaddressed 2026-04-02
Other Monitoring Unaddressed 2025-05-01
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
MR Monitoring Resolved 2021-12-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
497.2 µg/L 38%
of the EPA limit 1300 µg/L
worst single sample: 5150 µg/L
173/205 SYR4 2012–2018
Lead
50.375 µg/L 336%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 190 µg/L
134/205 SYR4 2012–2018
Nitrate
298.25 µg/L 3%
of the EPA limit 10000 µg/L
worst single sample: 305 µg/L
24/28 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
19/19 LCR 2024
Combined Radium (-226 And -228)
3.03 pCi/L 61%
of the EPA limit 5 pCi/L
worst single sample: 3.3 pCi/L
13/13 SYR4 2012–2018
Gross Beta Particle Activity
11.58 pCi/L
No EPA limit set
worst single sample: 11.7 pCi/L
13/13 SYR4 2012–2018
Bromoform
6.0595 µg/L
No EPA limit set
worst single sample: 6.34 µg/L
12/15 SYR4 2013–2019
Combined Uranium
15.15 µg/L 51%
of the EPA limit 30 µg/L
worst single sample: 15.3 µg/L
11/11 SYR4 2013–2018
Gross Alpha, Excl. Radon And U
14 pCi/L 93%
of the EPA limit 15 pCi/L
worst single sample: 15 pCi/L
11/11 SYR4 2013–2018
Dibromochloromethane
4.468 µg/L
No EPA limit set
worst single sample: 5.28 µg/L
9/15 SYR4 2013–2019
TTHM
6.477 µg/L 8.1%
of the EPA limit 80 µg/L
worst single sample: 6.75 µg/L
7/8 SYR4 2013–2019
Nitrate-Nitrite
293.75 µg/L 2.9%
of the EPA limit 10000 µg/L
worst single sample: 305 µg/L
6/8 SYR4 2012–2015
Barium
42.52 µg/L 2.1%
of the EPA limit 2000 µg/L
worst single sample: 44.9 µg/L
5/5 SYR4 2012–2017
Chromium
7.96 µg/L 8%
of the EPA limit 100 µg/L
worst single sample: 8.1 µg/L
5/5 SYR4 2012–2017
Fluoride
2266 µg/L 57%
of the EPA limit 4000 µg/L
worst single sample: 2350 µg/L
5/5 SYR4 2012–2017
Total Haloacetic Acids (HAA5)
2.36 µg/L 3.9%
of the EPA limit 60 µg/L
worst single sample: 2.4 µg/L
5/8 SYR4 2013–2019
Bromodichloromethane
2.653 µg/L
No EPA limit set
worst single sample: 2.8 µg/L
3/15 SYR4 2013–2019
Dibromoacetic Acid
2.35 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
3/8 SYR4 2013–2019
Arsenic
1.765 µg/L 18%
of the EPA limit 10 µg/L
worst single sample: 1.8 µg/L
2/5 SYR4 2012–2017
Selenium
8.775 µg/L 18%
of the EPA limit 50 µg/L
worst single sample: 8.9 µg/L
2/5 SYR4 2012–2017
Lithium
57.5 µg/L
No EPA limit set
2/2 UCMR-5 2023
Monochloroacetic Acid
2.2 µg/L
No EPA limit set
1/8 SYR4 2013–2019
Trichloroacetic Acid
1.5 µg/L
No EPA limit set
1/8 SYR4 2013–2019
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HURT, RUBEN
Phone
325-728-3464

Frequently asked questions about City of Colorado City

Is City of Colorado City tap water safe to drink?

EPA monitoring detected 23 contaminants in City of Colorado City's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Colorado City's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.

How many people does City of Colorado City serve?

City of Colorado City reports serving 3,991 people in Texas, per its EPA record.

Has City of Colorado City had any water quality violations?

The EPA has 38 violations on file for City of Colorado City, of which 4 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.