← Texas

Tap water quality report

Foothills Mobile Home Ranch

EPA monitoring tested this supplier for 79 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
21
detected
182
people served
75
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Kendall

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

75
health-based violations
271
violations on file
7
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
TT Health-based Unaddressed 2024-10-17
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-04-01 → 2023-06-30
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31
MCL Health-based Resolved 2023-01-01 → 2023-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
240 µg/L 2.4%
of the EPA limit 10000 µg/L
worst single sample: 320 µg/L
46/48 SYR4 2012–2019
Fluoride
4766 µg/L 119%
of the EPA limit, at the 95th percentile of samples — 4000 µg/L
worst single sample: 4870 µg/L
25/25 SYR4 2012–2019
Bromoform
9.05 µg/L
No EPA limit set
worst single sample: 14 µg/L
19/23 SYR4 2012–2019
Dibromochloromethane
9.375 µg/L
No EPA limit set
worst single sample: 18 µg/L
16/23 SYR4 2012–2019
Copper
66.6 µg/L 5.1%
of the EPA limit 1300 µg/L
worst single sample: 110 µg/L
15/21 SYR4 2012–2017
Bromodichloromethane
8 µg/L
No EPA limit set
worst single sample: 12 µg/L
11/23 SYR4 2012–2019
Barium
22.245 µg/L 1.1%
of the EPA limit 2000 µg/L
worst single sample: 22.7 µg/L
8/8 SYR4 2012–2019
Nitrate-Nitrite
278 µg/L 2.8%
of the EPA limit 10000 µg/L
worst single sample: 320 µg/L
8/9 SYR4 2012–2019
Gross Beta Particle Activity
14.8 pCi/L
No EPA limit set
6/6 SYR4 2012–2018
Lead
0.0011 mg/L 7.4%
of the EPA limit 0.0150 mg/L
6/6 LCR 2023
Combined Radium (-226 And -228)
2.932 pCi/L 59%
of the EPA limit 5 pCi/L
worst single sample: 3.4 pCi/L
5/6 SYR4 2012–2018
Lead
2.22 µg/L 15%
of the EPA limit 15 µg/L
worst single sample: 2.4 µg/L
5/21 SYR4 2012–2017
Selenium
8.44 µg/L 17%
of the EPA limit 50 µg/L
worst single sample: 8.8 µg/L
5/8 SYR4 2012–2019
Chloroform
6.43 µg/L
No EPA limit set
worst single sample: 7 µg/L
4/23 SYR4 2012–2019
Dibromoacetic Acid
2.14 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
4/4 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
8.305 pCi/L 55%
of the EPA limit 15 pCi/L
worst single sample: 8.5 pCi/L
4/4 SYR4 2014–2018
TTHM
13.24 µg/L 17%
of the EPA limit 80 µg/L
worst single sample: 14.2 µg/L
4/4 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
2.14 µg/L 3.6%
of the EPA limit 60 µg/L
worst single sample: 2.2 µg/L
4/4 SYR4 2013–2019
Arsenic
2.58 µg/L 26%
of the EPA limit 10 µg/L
worst single sample: 2.6 µg/L
2/8 SYR4 2012–2019
Chromium
0.3990 µg/L 0.4%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Thallium, Total
0.0070 µg/L 0.4%
of the EPA limit 2 µg/L
1/8 SYR4 2012–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
KNUPP, MAGGI, M
Phone
830-249-2229
Email
[email protected]

Frequently asked questions about Foothills Mobile Home Ranch

Is Foothills Mobile Home Ranch tap water safe to drink?

EPA monitoring detected 21 contaminants in Foothills Mobile Home Ranch's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Foothills Mobile Home Ranch's water?

EPA monitoring detected Nitrate, Fluoride, Bromoform, Dibromochloromethane, Copper, and others. The full list with the level and data source for each is above.

How many people does Foothills Mobile Home Ranch serve?

Foothills Mobile Home Ranch reports serving 182 people in Texas, per its EPA record.

Has Foothills Mobile Home Ranch had any water quality violations?

The EPA has 271 violations on file for Foothills Mobile Home Ranch, of which 75 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.