← Texas

Tap water quality report

Harris County Mud 130

EPA monitoring tested this supplier for 109 contaminants and detected 30. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
30
detected
4,572
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
18
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2022-05-30
Other Monitoring Resolved 2022-05-30
MON Monitoring Resolved 2022-03-01 → 2022-03-31
MON Monitoring Resolved 2022-03-01 → 2022-03-31
MON Monitoring Resolved 2022-03-01 → 2022-03-31
MON Monitoring Resolved 2022-03-01 → 2022-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31
MR Monitoring Resolved 2021-01-01 → 2021-03-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0052 µg/L 1/3 2024
PFBS 0.0030 µg/L 1/3 2024
Pfhxa 0.0045 µg/L 1/3 2024
Pfpea 0.0050 µg/L 1/3 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
10.01 µg/L
No EPA limit set
worst single sample: 13.5 µg/L
67/67 SYR4 2012–2019
Chloroform
25.1 µg/L
No EPA limit set
worst single sample: 54.3 µg/L
67/67 SYR4 2012–2019
Dichloroacetic Acid
29.775 µg/L
No EPA limit set
worst single sample: 50 µg/L
62/62 SYR4 2012–2019
TTHM
33.265 µg/L 42%
of the EPA limit 80 µg/L
worst single sample: 69.1 µg/L
62/62 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
40 µg/L 67%
of the EPA limit 60 µg/L
worst single sample: 82.4 µg/L
62/62 SYR4 2012–2019
Trichloroacetic Acid
8.925 µg/L
No EPA limit set
worst single sample: 17 µg/L
62/62 SYR4 2012–2019
Dibromochloromethane
3.9 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
61/67 SYR4 2012–2019
Copper
560.4 µg/L 43%
of the EPA limit 1300 µg/L
worst single sample: 845 µg/L
54/61 SYR4 2013–2017
Dibromoacetic Acid
2.165 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
48/62 SYR4 2012–2019
Lead
4.13 µg/L 28%
of the EPA limit 15 µg/L
worst single sample: 4.7 µg/L
20/61 SYR4 2013–2017
Nitrate
700 µg/L 7%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Atrazine
0.4650 µg/L 16%
of the EPA limit 3 µg/L
worst single sample: 0.6400 µg/L
11/13 SYR4 2012–2019
Lead
0.0011 mg/L 7.5%
of the EPA limit 0.0150 mg/L
11/11 LCR 2023
Monochloroacetic Acid
12.485 µg/L
No EPA limit set
worst single sample: 15.5 µg/L
10/62 SYR4 2012–2019
Simazine
0.2580 µg/L 6.5%
of the EPA limit 4 µg/L
worst single sample: 0.3300 µg/L
10/13 SYR4 2012–2019
Bromoform
1.48 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
5/67 SYR4 2012–2019
Fluoride
399 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 400 µg/L
3/3 SYR4 2012–2018
Nitrate-Nitrite
641 µg/L 6.4%
of the EPA limit 10000 µg/L
worst single sample: 660 µg/L
3/3 SYR4 2013–2019
Barium
103.575 µg/L 5.2%
of the EPA limit 2000 µg/L
worst single sample: 104 µg/L
2/2 SYR4 2015–2018
Combined Radium (-226 And -228)
1.475 pCi/L 30%
of the EPA limit 5 pCi/L
worst single sample: 1.5 pCi/L
2/2 SYR4 2012–2018
Cyanide
100 µg/L 50%
of the EPA limit 200 µg/L
1/2 SYR4 2014–2017
Combined Uranium
1.7 µg/L 5.7%
of the EPA limit 30 µg/L
1/1 SYR4 2018
Gross Beta Particle Activity
5.6 pCi/L
No EPA limit set
1/2 SYR4 2012–2018
Methoxychlor
0.2100 µg/L 0.5%
of the EPA limit 40 µg/L
1/13 SYR4 2012–2019
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
1/3 SYR4 2013–2019
Lithium
10.6 µg/L
No EPA limit set
1/4 UCMR-5 2024
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMonobromoacetic AcidNetfosaaNfdhaNmefosaaOxamylPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WEBSTER, MARC
Phone
713-651-3601

Frequently asked questions about Harris County Mud 130

Is Harris County Mud 130 tap water safe to drink?

EPA monitoring detected 30 contaminants in Harris County Mud 130's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Harris County Mud 130's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Harris County Mud 130 serve?

Harris County Mud 130 reports serving 4,572 people in Texas, per its EPA record.

Has Harris County Mud 130 had any water quality violations?

The EPA has 18 violations on file for Harris County Mud 130, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.