← Texas

Tap water quality report

Windfern Forest Utility District

EPA monitoring tested this supplier for 109 contaminants and detected 30. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
30
detected
7,170
people served
26
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Harris

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

26
health-based violations
35
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2005-01-01 → 2005-03-31
MCL Health-based Resolved 2004-03-01 → 2004-06-30
MCL Health-based Resolved 2004-03-01 → 2004-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0053 µg/L 1/4 2025
Pfhxa 0.0037 µg/L 1/4 2025
Pfpea 0.0040 µg/L 1/4 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
175.795 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 273 µg/L
108/109 SYR4 2012–2017
Lead
16.85 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 103 µg/L
102/109 SYR4 2012–2017
Nitrate
546.5 µg/L 5.5%
of the EPA limit 10000 µg/L
worst single sample: 550 µg/L
28/32 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
10.965 pCi/L 73%
of the EPA limit 15 pCi/L
worst single sample: 14 pCi/L
22/26 SYR4 2012–2019
Gross Beta Particle Activity
15.9 pCi/L
No EPA limit set
worst single sample: 16.7 pCi/L
21/27 SYR4 2012–2019
Combined Radium (-226 And -228)
3.075 pCi/L 62%
of the EPA limit 5 pCi/L
worst single sample: 4.5 pCi/L
20/23 SYR4 2012–2019
Combined Uranium
34.665 µg/L 116%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 35.9 µg/L
20/26 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
18/18 LCR 2024
Dibromochloromethane
4 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
9/17 SYR4 2013–2019
Bromodichloromethane
7.26 µg/L
No EPA limit set
worst single sample: 7.4 µg/L
8/17 SYR4 2013–2019
Bromoform
2.55 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
6/17 SYR4 2013–2019
Chloroform
13.725 µg/L
No EPA limit set
worst single sample: 14 µg/L
6/17 SYR4 2013–2019
Nitrate-Nitrite
445 µg/L 4.5%
of the EPA limit 10000 µg/L
worst single sample: 560 µg/L
6/6 SYR4 2012–2015
Barium
244.6 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 245 µg/L
5/5 SYR4 2013–2019
Fluoride
527 µg/L 13%
of the EPA limit 4000 µg/L
worst single sample: 560 µg/L
4/4 SYR4 2014–2017
Arsenic
8.85 µg/L 89%
of the EPA limit 10 µg/L
worst single sample: 9.3 µg/L
3/5 SYR4 2013–2019
Atrazine
0.1280 µg/L 4.3%
of the EPA limit 3 µg/L
worst single sample: 0.1300 µg/L
3/10 SYR4 2012–2019
Dibromoacetic Acid
1.96 µg/L
No EPA limit set
worst single sample: 2 µg/L
3/7 SYR4 2013–2019
TTHM
17.46 µg/L 22%
of the EPA limit 80 µg/L
worst single sample: 18.7 µg/L
3/7 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
22.84 µg/L 38%
of the EPA limit 60 µg/L
worst single sample: 25.2 µg/L
3/7 SYR4 2013–2019
Lithium
37.9 µg/L
No EPA limit set
3/4 UCMR-5 2025
Cyanide
70 µg/L 35%
of the EPA limit 200 µg/L
1/4 SYR4 2014–2017
Dichloroacetic Acid
17.2 µg/L
No EPA limit set
1/7 SYR4 2013–2019
Nitrite
10 µg/L 1%
of the EPA limit 1000 µg/L
1/6 SYR4 2012–2015
Selenium
10.1 µg/L 20%
of the EPA limit 50 µg/L
1/5 SYR4 2013–2019
Simazine
0.1000 µg/L 2.5%
of the EPA limit 4 µg/L
1/10 SYR4 2012–2019
Trichloroacetic Acid
6 µg/L
No EPA limit set
1/7 SYR4 2013–2019
79 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MENDEL, EDDIE, H
Phone
713-937-0218

Frequently asked questions about Windfern Forest Utility District

Is Windfern Forest Utility District tap water safe to drink?

EPA monitoring detected 30 contaminants in Windfern Forest Utility District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Windfern Forest Utility District's water?

EPA monitoring detected Copper, Lead, Nitrate, Gross Alpha, Excl. Radon And U, Gross Beta Particle Activity, and others. The full list with the level and data source for each is above.

How many people does Windfern Forest Utility District serve?

Windfern Forest Utility District reports serving 7,170 people in Texas, per its EPA record.

Has Windfern Forest Utility District had any water quality violations?

The EPA has 35 violations on file for Windfern Forest Utility District, of which 26 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.