← Texas

Tap water quality report

City of Silsbee

EPA monitoring tested this supplier for 109 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
17
detected
10,026
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Hardin

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
16
violations on file
3
still open
ViolationTypeStatusPeriod
MR Monitoring Unaddressed 2025-10-01
MR Monitoring Unaddressed 2025-10-01
MR Monitoring Unaddressed 2025-10-01
RPT Monitoring Resolved 2025-07-02
RPT Monitoring Resolved 2025-07-02
Other Monitoring Resolved 2018-08-16
Other Monitoring Resolved 2018-08-16
MR Monitoring Resolved 2016-08-25
MR Monitoring Resolved 2016-08-25
MR Monitoring Resolved 2016-08-25

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
245.6 µg/L 19%
of the EPA limit 1300 µg/L
worst single sample: 358 µg/L
52/66 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Nitrate
20 µg/L 0.2%
of the EPA limit 10000 µg/L
8/48 SYR4 2012–2019
Chloroform
5.16 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
7/27 SYR4 2013–2019
Combined Radium (-226 And -228)
3.64 pCi/L 73%
of the EPA limit 5 pCi/L
worst single sample: 3.7 pCi/L
7/7 SYR4 2013–2019
Barium
488.75 µg/L 24%
of the EPA limit 2000 µg/L
worst single sample: 494 µg/L
6/6 SYR4 2014–2017
Fluoride
645 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 740 µg/L
6/6 SYR4 2014–2017
Lithium
11.8 µg/L
No EPA limit set
6/6 UCMR-5 2025
Gross Alpha, Excl. Radon And U
9.5 pCi/L 63%
of the EPA limit 15 pCi/L
worst single sample: 9.8 pCi/L
5/5 SYR4 2016–2019
Gross Beta Particle Activity
6.62 pCi/L
No EPA limit set
worst single sample: 6.7 pCi/L
5/7 SYR4 2013–2019
Arsenic
4.085 µg/L 41%
of the EPA limit 10 µg/L
worst single sample: 4.1 µg/L
4/6 SYR4 2014–2017
Bromodichloromethane
4.32 µg/L
No EPA limit set
worst single sample: 4.5 µg/L
3/27 SYR4 2013–2019
Lead
2.272 µg/L 15%
of the EPA limit 15 µg/L
worst single sample: 2.31 µg/L
3/66 SYR4 2013–2019
Xylenes, Total
1.57 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 1.6 µg/L
3/18 SYR4 2015–2019
TTHM
3.95 µg/L 4.9%
of the EPA limit 80 µg/L
worst single sample: 4.1 µg/L
2/9 SYR4 2013–2019
Dibromochloromethane
2.5 µg/L
No EPA limit set
1/27 SYR4 2013–2019
Nitrate-Nitrite
20 µg/L 0.2%
of the EPA limit 10000 µg/L
1/9 SYR4 2012–2015
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RENEAU, DANNY
Phone
409-385-3535

Frequently asked questions about City of Silsbee

Is City of Silsbee tap water safe to drink?

EPA monitoring detected 17 contaminants in City of Silsbee's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Silsbee's water?

EPA monitoring detected Copper, Lead, Nitrate, Chloroform, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.

How many people does City of Silsbee serve?

City of Silsbee reports serving 10,026 people in Texas, per its EPA record.

Has City of Silsbee had any water quality violations?

The EPA has 16 violations on file for City of Silsbee, of which 0 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.