← Texas

Tap water quality report

Springs Hill Sud

EPA monitoring tested this supplier for 109 contaminants and detected 27. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
27
detected
35,541
people served
68
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Guadalupe

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

68
health-based violations
283
violations on file
6
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfpea 0.0035 µg/L 2/10 2024
Pfba 0.0054 µg/L 1/10 2024
PFOS 0.0044 µg/L 1/10 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
376 µg/L 29%
of the EPA limit 1300 µg/L
worst single sample: 919 µg/L
169/187 SYR4 2013–2019
Dibromochloromethane
22.86 µg/L
No EPA limit set
worst single sample: 34.6 µg/L
135/141 SYR4 2012–2019
TTHM
103.94 µg/L 130%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 135 µg/L
127/128 SYR4 2012–2019
Bromoform
8.8 µg/L
No EPA limit set
worst single sample: 14.7 µg/L
123/141 SYR4 2012–2019
Bromodichloromethane
37.61 µg/L
No EPA limit set
worst single sample: 44 µg/L
119/141 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
58.36 µg/L 97%
of the EPA limit 60 µg/L
worst single sample: 78.4 µg/L
110/128 SYR4 2012–2019
Chloroform
56.8 µg/L
No EPA limit set
worst single sample: 89.4 µg/L
101/141 SYR4 2012–2019
Dibromoacetic Acid
8.1 µg/L
No EPA limit set
worst single sample: 9.2 µg/L
99/128 SYR4 2012–2019
Dichloroacetic Acid
38.89 µg/L
No EPA limit set
worst single sample: 59.3 µg/L
99/128 SYR4 2012–2019
Trichloroacetic Acid
11.82 µg/L
No EPA limit set
worst single sample: 21.5 µg/L
79/128 SYR4 2012–2019
Nitrate
1520 µg/L 15%
of the EPA limit 10000 µg/L
worst single sample: 1610 µg/L
54/68 SYR4 2012–2019
Lead
20.92 µg/L 139%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 39.4 µg/L
37/187 SYR4 2013–2019
Monochloroacetic Acid
8.58 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
23/128 SYR4 2012–2019
Monobromoacetic Acid
3.71 µg/L
No EPA limit set
worst single sample: 6.5 µg/L
19/128 SYR4 2012–2019
Lead
0.0011 mg/L 7.5%
of the EPA limit 0.0150 mg/L
17/17 LCR 2025
Barium
109 µg/L 5.5%
of the EPA limit 2000 µg/L
10/10 SYR4 2013–2019
Fluoride
234 µg/L 5.9%
of the EPA limit 4000 µg/L
worst single sample: 250 µg/L
9/10 SYR4 2012–2019
Nitrate-Nitrite
1577 µg/L 16%
of the EPA limit 10000 µg/L
worst single sample: 1610 µg/L
7/10 SYR4 2012–2015
Lithium
36.3 µg/L
No EPA limit set
5/10 UCMR-5 2024
Dalapon
1.085 µg/L 0.5%
of the EPA limit 200 µg/L
worst single sample: 1.1 µg/L
4/117 SYR4 2013–2019
Gross Beta Particle Activity
9.87 pCi/L
No EPA limit set
worst single sample: 9.9 pCi/L
3/5 SYR4 2012–2017
Gross Alpha, Excl. Radon And U
5.865 pCi/L 39%
of the EPA limit 15 pCi/L
worst single sample: 6 pCi/L
2/3 SYR4 2014–2017
Xylenes, Total
0.7000 µg/L 0%
of the EPA limit 10000 µg/L
2/13 SYR4 2012–2019
Combined Radium (-226 And -228)
2.23 pCi/L 45%
of the EPA limit 5 pCi/L
1/1 SYR4 2017
82 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MARTIN, JAMES
Phone
830-303-8624

Frequently asked questions about Springs Hill Sud

Is Springs Hill Sud tap water safe to drink?

EPA monitoring detected 27 contaminants in Springs Hill Sud's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Springs Hill Sud's water?

EPA monitoring detected Copper, Dibromochloromethane, TTHM, Bromoform, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Springs Hill Sud serve?

Springs Hill Sud reports serving 35,541 people in Texas, per its EPA record.

Has Springs Hill Sud had any water quality violations?

The EPA has 283 violations on file for Springs Hill Sud, of which 68 are health-based (a contaminant limit or required treatment was breached) and 6 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.