← Texas

Tap water quality report

City of Ennis

EPA monitoring tested this supplier for 108 contaminants and detected 30. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
30
detected
24,891
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Ellis

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
1
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2013-12-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0120 µg/L 4/4 2023
PFBS 0.0072 µg/L 4/4 2023
Pfhxa 0.0132 µg/L 4/4 2023
Pfpea 0.0173 µg/L 4/4 2023

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
26.62 µg/L
No EPA limit set
worst single sample: 31.1 µg/L
115/115 SYR4 2012–2019
Chloroform
34.23 µg/L
No EPA limit set
worst single sample: 41 µg/L
115/115 SYR4 2012–2019
Dibromochloromethane
19.99 µg/L
No EPA limit set
worst single sample: 27.5 µg/L
115/115 SYR4 2012–2019
Dichloroacetic Acid
15.31 µg/L
No EPA limit set
worst single sample: 16.7 µg/L
107/107 SYR4 2012–2019
TTHM
70.2 µg/L 88%
of the EPA limit 80 µg/L
worst single sample: 84.4 µg/L
107/108 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
30.39 µg/L 51%
of the EPA limit 60 µg/L
worst single sample: 46.1 µg/L
107/107 SYR4 2012–2019
Trichloroacetic Acid
12.51 µg/L
No EPA limit set
worst single sample: 14.9 µg/L
107/107 SYR4 2012–2019
Bromoform
6.26 µg/L
No EPA limit set
worst single sample: 8.1 µg/L
95/115 SYR4 2012–2019
Copper
360 µg/L 28%
of the EPA limit 1300 µg/L
worst single sample: 1500 µg/L
93/95 SYR4 2013–2019
Dibromoacetic Acid
6.375 µg/L
No EPA limit set
worst single sample: 7.2 µg/L
82/107 SYR4 2012–2019
Monobromoacetic Acid
2.935 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
54/107 SYR4 2012–2019
Monochloroacetic Acid
6.14 µg/L
No EPA limit set
worst single sample: 21.8 µg/L
33/107 SYR4 2012–2019
Lead
5.4725 µg/L 36%
of the EPA limit 15 µg/L
worst single sample: 87.7 µg/L
28/95 SYR4 2013–2019
Nitrate
838 µg/L 8.4%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Atrazine
0.2572 µg/L 8.6%
of the EPA limit 3 µg/L
worst single sample: 0.2800 µg/L
9/11 SYR4 2012–2019
Fluoride
645.2 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 655 µg/L
8/8 SYR4 2012–2019
Barium
68.7 µg/L 3.4%
of the EPA limit 2000 µg/L
worst single sample: 69 µg/L
7/7 SYR4 2013–2019
Arsenic
1.71 µg/L 17%
of the EPA limit 10 µg/L
worst single sample: 1.8 µg/L
4/7 SYR4 2013–2019
Cyanide
139.7 µg/L 70%
of the EPA limit 200 µg/L
worst single sample: 140 µg/L
4/6 SYR4 2014–2019
Chromium
2.675 µg/L 2.7%
of the EPA limit 100 µg/L
worst single sample: 2.9 µg/L
4/7 SYR4 2013–2019
Antimony, Total
0.2598 µg/L 4.3%
of the EPA limit 6 µg/L
worst single sample: 0.2600 µg/L
3/7 SYR4 2013–2019
Simazine
0.0506 µg/L 1.3%
of the EPA limit 4 µg/L
worst single sample: 0.0506 µg/L
2/11 SYR4 2012–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
1/1 SYR4 2017
Gross Beta Particle Activity
6.5 pCi/L
No EPA limit set
1/1 SYR4 2017
Selenium
3.9 µg/L 7.8%
of the EPA limit 50 µg/L
1/7 SYR4 2013–2019
78 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RABURN, KAMERON
Phone
972-875-1234

Frequently asked questions about City of Ennis

Is City of Ennis tap water safe to drink?

EPA monitoring detected 30 contaminants in City of Ennis's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Ennis's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does City of Ennis serve?

City of Ennis reports serving 24,891 people in Texas, per its EPA record.

Has City of Ennis had any water quality violations?

The EPA has 1 violation on file for City of Ennis, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.