← Texas

Tap water quality report

Parkerville East Mobile Home Park

EPA monitoring tested this supplier for 79 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
18
detected
42
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Dallas

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
39
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
Other Monitoring Unaddressed 2025-10-26
Other Monitoring Resolved 2025-05-15
Other Monitoring Resolved 2025-05-15
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
250 µg/L 2.5%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Copper
53.71 µg/L 4.1%
of the EPA limit 1300 µg/L
worst single sample: 54.4 µg/L
7/7 SYR4 2012–2018
Bromoform
4.012 µg/L
No EPA limit set
worst single sample: 4.06 µg/L
4/8 SYR4 2015–2019
Barium
7.07 µg/L 0.4%
of the EPA limit 2000 µg/L
worst single sample: 7.1 µg/L
3/3 SYR4 2012–2019
Dibromochloromethane
2.927 µg/L
No EPA limit set
worst single sample: 2.97 µg/L
3/8 SYR4 2015–2019
Lead
2.765 µg/L 18%
of the EPA limit 15 µg/L
worst single sample: 2.93 µg/L
3/7 SYR4 2012–2018
Nitrate-Nitrite
92.5 µg/L 0.9%
of the EPA limit 10000 µg/L
worst single sample: 95 µg/L
3/3 SYR4 2012–2015
Chromium
3.18415 µg/L 3.2%
of the EPA limit 100 µg/L
worst single sample: 3.3 µg/L
2/3 SYR4 2012–2019
Fluoride
1852.5 µg/L 46%
of the EPA limit 4000 µg/L
worst single sample: 1870 µg/L
2/2 SYR4 2014–2017
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
2/2 LCR 2025
Styrene
0.7690 µg/L 0.8%
of the EPA limit 100 µg/L
worst single sample: 0.7800 µg/L
2/6 SYR4 2015–2019
Bromodichloromethane
1.06 µg/L
No EPA limit set
1/8 SYR4 2015–2019
Combined Radium (-226 And -228)
1 pCi/L 20%
of the EPA limit 5 pCi/L
1/1 SYR4 2012
Gross Beta Particle Activity
4 pCi/L
No EPA limit set
1/2 SYR4 2012–2018
Monobromoacetic Acid
1.1 µg/L
No EPA limit set
1/2 SYR4 2016–2019
TTHM
6.31 µg/L 7.9%
of the EPA limit 80 µg/L
1/2 SYR4 2016–2019
Total Haloacetic Acids (HAA5)
2.9 µg/L 4.8%
of the EPA limit 60 µg/L
1/2 SYR4 2016–2019
Trichloroacetic Acid
1.8 µg/L
No EPA limit set
1/2 SYR4 2016–2019
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JOHNSON, LOVELL
Phone
972-223-7348
Email
[email protected]

Frequently asked questions about Parkerville East Mobile Home Park

Is Parkerville East Mobile Home Park tap water safe to drink?

EPA monitoring detected 18 contaminants in Parkerville East Mobile Home Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Parkerville East Mobile Home Park's water?

EPA monitoring detected Nitrate, Copper, Bromoform, Barium, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Parkerville East Mobile Home Park serve?

Parkerville East Mobile Home Park reports serving 42 people in Texas, per its EPA record.

Has Parkerville East Mobile Home Park had any water quality violations?

The EPA has 39 violations on file for Parkerville East Mobile Home Park, of which 4 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.