Tap water quality report

Clwsc Canyon Lake Shores

EPA monitoring tested this supplier for 110 contaminants and detected 36. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
36
detected
44,196
people served
57
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Comal

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

57
health-based violations
161
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfba 0.0071 µg/L 2/32 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2316 µg/L 23%
of the EPA limit 10000 µg/L
worst single sample: 2680 µg/L
262/270 SYR4 2012–2019
Dibromochloromethane
23.5 µg/L
No EPA limit set
worst single sample: 30.6 µg/L
196/228 SYR4 2012–2019
Bromodichloromethane
26.76 µg/L
No EPA limit set
worst single sample: 39 µg/L
189/228 SYR4 2012–2019
Bromoform
7.9 µg/L
No EPA limit set
worst single sample: 62 µg/L
185/228 SYR4 2012–2019
Chloroform
24.3 µg/L
No EPA limit set
worst single sample: 77 µg/L
177/228 SYR4 2012–2019
Chlorite
620.5 µg/L 62%
of the EPA limit 1000 µg/L
worst single sample: 720 µg/L
160/210 SYR4 2013–2019
TTHM
80.44 µg/L 101%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 96.4 µg/L
129/131 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
22.84 µg/L 38%
of the EPA limit 60 µg/L
worst single sample: 36.1 µg/L
129/131 SYR4 2012–2019
Dibromoacetic Acid
8 µg/L
No EPA limit set
worst single sample: 9.1 µg/L
124/131 SYR4 2012–2019
Dichloroacetic Acid
11.84 µg/L
No EPA limit set
worst single sample: 21.3 µg/L
120/131 SYR4 2012–2019
Copper
187.7 µg/L 14%
of the EPA limit 1300 µg/L
worst single sample: 299 µg/L
119/131 SYR4 2012–2019
Trichloroacetic Acid
4.93 µg/L
No EPA limit set
worst single sample: 17.7 µg/L
88/131 SYR4 2012–2019
Fluoride
1284 µg/L 32%
of the EPA limit 4000 µg/L
worst single sample: 2100 µg/L
57/57 SYR4 2012–2019
Barium
43.25 µg/L 2.2%
of the EPA limit 2000 µg/L
worst single sample: 111 µg/L
56/56 SYR4 2012–2019
Lead
6.36 µg/L 42%
of the EPA limit 15 µg/L
worst single sample: 10.2 µg/L
53/131 SYR4 2012–2019
Monobromoacetic Acid
2 µg/L
No EPA limit set
worst single sample: 4 µg/L
41/131 SYR4 2012–2019
Nitrate-Nitrite
2618 µg/L 26%
of the EPA limit 10000 µg/L
worst single sample: 2680 µg/L
23/26 SYR4 2012–2019
Combined Radium (-226 And -228)
2.52 pCi/L 50%
of the EPA limit 5 pCi/L
worst single sample: 2.8 pCi/L
15/16 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
6.06 pCi/L 40%
of the EPA limit 15 pCi/L
worst single sample: 6.2 pCi/L
15/32 SYR4 2013–2019
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
14/14 LCR 2026
Gross Beta Particle Activity
11.5 pCi/L
No EPA limit set
worst single sample: 12.1 pCi/L
11/36 SYR4 2012–2019
Selenium
24.3 µg/L 49%
of the EPA limit 50 µg/L
worst single sample: 37.9 µg/L
11/56 SYR4 2012–2019
Monochloroacetic Acid
2.91 µg/L
No EPA limit set
worst single sample: 3 µg/L
10/131 SYR4 2012–2019
Lithium
18.2 µg/L
No EPA limit set
7/32 UCMR-5 2025
Dichloromethane
1.25 µg/L 25%
of the EPA limit 5 µg/L
worst single sample: 1.3 µg/L
6/97 SYR4 2012–2019
Xylenes, Total
2.675 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 3.2 µg/L
6/97 SYR4 2012–2019
Combined Uranium
2.08 µg/L 6.9%
of the EPA limit 30 µg/L
worst single sample: 2.2 µg/L
5/32 SYR4 2013–2019
Arsenic
8.635 µg/L 86%
of the EPA limit 10 µg/L
worst single sample: 9.7 µg/L
4/55 SYR4 2012–2019
Chromium
3.7485 µg/L 3.7%
of the EPA limit 100 µg/L
worst single sample: 3.78 µg/L
4/56 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
1.1655 µg/L 19%
of the EPA limit 6 µg/L
worst single sample: 1.2 µg/L
4/63 SYR4 2012–2019
Cyanide
48.5 µg/L 24%
of the EPA limit 200 µg/L
worst single sample: 50 µg/L
2/45 SYR4 2013–2019
Ethylbenzene
0.9750 µg/L 0.1%
of the EPA limit 700 µg/L
worst single sample: 1 µg/L
2/97 SYR4 2012–2019
Carbon Tetrachloride
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/97 SYR4 2012–2019
Nitrite
20 µg/L 2%
of the EPA limit 1000 µg/L
1/36 SYR4 2012–2019
Toluene
0.9000 µg/L 0.1%
of the EPA limit 1000 µg/L
1/97 SYR4 2012–2019
74 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranChlordaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WILLIAMS, AUNDREA
Phone
830-312-4600
Email
[email protected]

Frequently asked questions about Clwsc Canyon Lake Shores

Is Clwsc Canyon Lake Shores tap water safe to drink?

EPA monitoring detected 36 contaminants in Clwsc Canyon Lake Shores's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Clwsc Canyon Lake Shores's water?

EPA monitoring detected Nitrate, Dibromochloromethane, Bromodichloromethane, Bromoform, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Clwsc Canyon Lake Shores serve?

Clwsc Canyon Lake Shores reports serving 44,196 people in Texas, per its EPA record.

Has Clwsc Canyon Lake Shores had any water quality violations?

The EPA has 161 violations on file for Clwsc Canyon Lake Shores, of which 57 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.