← Texas

Tap water quality report

Bell County Wcid 1

EPA monitoring tested this supplier for 77 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
24
detected
216
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Bell

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
6
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2007-05-01 → 2007-05-31
MR Monitoring Resolved 2007-05-01 → 2007-05-31
MR Monitoring Resolved 2007-05-01 → 2007-05-31
MR Monitoring Resolved 2007-05-01 → 2007-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
650 µg/L 6.5%
of the EPA limit 10000 µg/L
worst single sample: 670 µg/L
54/54 SYR4 2012–2019
Bromodichloromethane
20.5 µg/L
No EPA limit set
worst single sample: 22.9 µg/L
31/31 SYR4 2012–2019
Chloroform
35.5 µg/L
No EPA limit set
worst single sample: 40.2 µg/L
31/31 SYR4 2012–2019
Dibromochloromethane
11.72 µg/L
No EPA limit set
worst single sample: 13 µg/L
29/31 SYR4 2012–2019
Fluoride
239 µg/L 6%
of the EPA limit 4000 µg/L
worst single sample: 240 µg/L
23/23 SYR4 2012–2019
Atrazine
0.3700 µg/L 12%
of the EPA limit 3 µg/L
21/25 SYR4 2012–2019
Barium
64.97 µg/L 3.2%
of the EPA limit 2000 µg/L
worst single sample: 66.3 µg/L
20/20 SYR4 2013–2019
Bromoform
4.315 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
18/31 SYR4 2012–2019
Cyanide
152 µg/L 76%
of the EPA limit 200 µg/L
worst single sample: 160 µg/L
17/17 SYR4 2014–2019
Copper
38.5 µg/L 3%
of the EPA limit 1300 µg/L
worst single sample: 42 µg/L
11/25 SYR4 2013–2017
Dibromoacetic Acid
3.95 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
8/8 SYR4 2012–2019
Dichloroacetic Acid
27.58 µg/L
No EPA limit set
worst single sample: 30.8 µg/L
8/8 SYR4 2012–2019
TTHM
62.32 µg/L 78%
of the EPA limit 80 µg/L
worst single sample: 70.3 µg/L
8/11 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
43.365 µg/L 72%
of the EPA limit 60 µg/L
worst single sample: 48.3 µg/L
8/8 SYR4 2012–2019
Trichloroacetic Acid
11.97 µg/L
No EPA limit set
worst single sample: 14.7 µg/L
8/8 SYR4 2012–2019
Arsenic
2.275 µg/L 23%
of the EPA limit 10 µg/L
worst single sample: 2.3 µg/L
6/20 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
6/6 LCR 2023
Chromium
1.779 µg/L 1.8%
of the EPA limit 100 µg/L
worst single sample: 1.78 µg/L
3/20 SYR4 2013–2019
Gross Beta Particle Activity
5.16 pCi/L
No EPA limit set
worst single sample: 5.2 pCi/L
3/3 SYR4 2015
Lead
2.13 µg/L 14%
of the EPA limit 15 µg/L
worst single sample: 2.2 µg/L
3/25 SYR4 2013–2017
Antimony, Total
0.2150 µg/L 3.6%
of the EPA limit 6 µg/L
worst single sample: 0.2150 µg/L
2/20 SYR4 2013–2019
Monochloroacetic Acid
7.37 µg/L
No EPA limit set
worst single sample: 7.6 µg/L
2/8 SYR4 2012–2019
Dalapon
8.54 µg/L 4.3%
of the EPA limit 200 µg/L
1/22 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.6900 µg/L 12%
of the EPA limit 6 µg/L
1/25 SYR4 2012–2019
53 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAsbestosBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROBINSON, ROBERT, R
Phone
254-698-4507
Email
[email protected]

Frequently asked questions about Bell County Wcid 1

Is Bell County Wcid 1 tap water safe to drink?

EPA monitoring detected 24 contaminants in Bell County Wcid 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bell County Wcid 1's water?

EPA monitoring detected Nitrate, Bromodichloromethane, Chloroform, Dibromochloromethane, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Bell County Wcid 1 serve?

Bell County Wcid 1 reports serving 216 people in Texas, per its EPA record.

Has Bell County Wcid 1 had any water quality violations?

The EPA has 6 violations on file for Bell County Wcid 1, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.