← Texas

Tap water quality report

City of Pleasanton

EPA monitoring tested this supplier for 109 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
24
detected
17,985
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Atascosa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
53
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2025-07-02
MR Monitoring Resolved 2020-12-30
MR Monitoring Resolved 2020-12-30
Other Monitoring Resolved 2019-03-10
Other Monitoring Resolved 2019-03-10
Other Monitoring Resolved 2019-03-10
Other Monitoring Resolved 2019-03-10
Other Monitoring Resolved 2019-03-10
Other Monitoring Resolved 2019-03-10
Other Monitoring Resolved 2019-03-10

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
301.4 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 804 µg/L
169/191 SYR4 2013–2017
Bromoform
17.52 µg/L
No EPA limit set
worst single sample: 26.4 µg/L
130/145 SYR4 2012–2019
Dibromochloromethane
6.925 µg/L
No EPA limit set
worst single sample: 15 µg/L
126/145 SYR4 2012–2019
TTHM
25.96 µg/L 32%
of the EPA limit 80 µg/L
worst single sample: 36.5 µg/L
109/110 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.4 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 10.4 µg/L
79/110 SYR4 2012–2019
Dibromoacetic Acid
4.65 µg/L
No EPA limit set
worst single sample: 6.2 µg/L
75/110 SYR4 2012–2019
Bromodichloromethane
3.18 µg/L
No EPA limit set
worst single sample: 9.5 µg/L
65/145 SYR4 2012–2019
Lead
5.5 µg/L 37%
of the EPA limit 15 µg/L
worst single sample: 29 µg/L
41/191 SYR4 2013–2017
Nitrate
30 µg/L 0.3%
of the EPA limit 10000 µg/L
26/82 SYR4 2012–2019
Lead
0.0013 mg/L 8.7%
of the EPA limit 0.0150 mg/L
16/16 LCR 2023
Lithium
105.7 µg/L
No EPA limit set
12/12 UCMR-5 2025
Barium
235.5 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 237 µg/L
11/11 SYR4 2014–2017
Fluoride
485 µg/L 12%
of the EPA limit 4000 µg/L
worst single sample: 490 µg/L
11/11 SYR4 2014–2017
Combined Radium (-226 And -228)
3.74 pCi/L 75%
of the EPA limit 5 pCi/L
worst single sample: 3.9 pCi/L
9/9 SYR4 2014–2017
Gross Beta Particle Activity
12.26 pCi/L
No EPA limit set
worst single sample: 12.7 pCi/L
9/9 SYR4 2014–2017
Gross Alpha, Excl. Radon And U
6.75 pCi/L 45%
of the EPA limit 15 pCi/L
worst single sample: 7.2 pCi/L
7/9 SYR4 2014–2017
Monochloroacetic Acid
8.82 µg/L
No EPA limit set
worst single sample: 9.3 µg/L
7/110 SYR4 2012–2019
Chloroform
5.825 µg/L
No EPA limit set
worst single sample: 7.1 µg/L
6/145 SYR4 2012–2019
Nitrate-Nitrite
28 µg/L 0.3%
of the EPA limit 10000 µg/L
worst single sample: 30 µg/L
5/19 SYR4 2012–2019
Xylenes, Total
12.16 µg/L 0.1%
of the EPA limit 10000 µg/L
worst single sample: 14 µg/L
5/35 SYR4 2014–2019
Ethylbenzene
1.6 µg/L 0.2%
of the EPA limit 700 µg/L
worst single sample: 1.7 µg/L
3/35 SYR4 2014–2019
Selenium
6.93 µg/L 14%
of the EPA limit 50 µg/L
worst single sample: 7 µg/L
3/11 SYR4 2014–2017
Arsenic
2.1 µg/L 21%
of the EPA limit 10 µg/L
1/11 SYR4 2014–2017
Dichloroacetic Acid
2.3 µg/L
No EPA limit set
1/110 SYR4 2012–2019
85 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GALLEGOS, JR
Phone
830-569-3867
Email
[email protected]

Frequently asked questions about City of Pleasanton

Is City of Pleasanton tap water safe to drink?

EPA monitoring detected 24 contaminants in City of Pleasanton's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Pleasanton's water?

EPA monitoring detected Copper, Bromoform, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does City of Pleasanton serve?

City of Pleasanton reports serving 17,985 people in Texas, per its EPA record.

Has City of Pleasanton had any water quality violations?

The EPA has 53 violations on file for City of Pleasanton, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.