← South Carolina

Tap water quality report

Wcwsa (sc4510007)

EPA monitoring tested this supplier for 108 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
19
detected
7,099
people served
17
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Williamsburg

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

17
health-based violations
19
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-10-01 → 2023-12-31
MCL Health-based Resolved 2023-09-01 → 2023-09-30
MCL Health-based Resolved 2023-09-01 → 2023-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
300 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 1800 µg/L
44/50 SYR4 2012–2018
Bromodichloromethane
23.36 µg/L
No EPA limit set
worst single sample: 37.39 µg/L
37/37 SYR4 2014–2019
Dibromochloromethane
30.46 µg/L
No EPA limit set
worst single sample: 43.45 µg/L
37/37 SYR4 2014–2019
TTHM
81.248 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 132.34 µg/L
37/37 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
20.352 µg/L 34%
of the EPA limit 60 µg/L
worst single sample: 27 µg/L
37/37 SYR4 2014–2019
Bromoform
8.953 µg/L
No EPA limit set
worst single sample: 22.54 µg/L
35/37 SYR4 2014–2019
Chloroform
18.9809 µg/L
No EPA limit set
worst single sample: 25.03 µg/L
34/37 SYR4 2014–2019
Dibromoacetic Acid
4.4555 µg/L
No EPA limit set
worst single sample: 5.74 µg/L
32/37 SYR4 2014–2019
Dichloroacetic Acid
11.315 µg/L
No EPA limit set
worst single sample: 20.28 µg/L
32/37 SYR4 2014–2019
Monobromoacetic Acid
10.5165 µg/L
No EPA limit set
worst single sample: 11.43 µg/L
32/37 SYR4 2014–2019
Trichloroacetic Acid
4.8605 µg/L
No EPA limit set
worst single sample: 5.65 µg/L
30/37 SYR4 2014–2019
Lead
8.24 µg/L 55%
of the EPA limit 15 µg/L
worst single sample: 66 µg/L
20/50 SYR4 2012–2018
Fluoride
2530 µg/L 63%
of the EPA limit 4000 µg/L
worst single sample: 2600 µg/L
15/15 SYR4 2013–2019
Lead
0.0027 mg/L 18%
of the EPA limit 0.0150 mg/L
11/11 LCR 2024
Nitrate
50 µg/L 0.5%
of the EPA limit 10000 µg/L
4/58 SYR4 2012–2019
Combined Radium (-226 And -228)
1.0521 pCi/L 21%
of the EPA limit 5 pCi/L
worst single sample: 1.1 pCi/L
2/5 SYR4 2015–2019
Gross Beta Particle Activity
6.4195 pCi/L
No EPA limit set
worst single sample: 6.51 pCi/L
2/2 SYR4 2019
Nitrate-Nitrite
32 µg/L 0.3%
of the EPA limit 10000 µg/L
1/4 SYR4 2019
Lithium
9.56 µg/L
No EPA limit set
1/8 UCMR-5 2024
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MIXON, LANE
Phone
843-355-9321
Email
[email protected]

Frequently asked questions about Wcwsa (sc4510007)

Is Wcwsa (sc4510007) tap water safe to drink?

EPA monitoring detected 19 contaminants in Wcwsa (sc4510007)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wcwsa (sc4510007)'s water?

EPA monitoring detected Copper, Bromodichloromethane, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Wcwsa (sc4510007) serve?

Wcwsa (sc4510007) reports serving 7,099 people in South Carolina, per its EPA record.

Has Wcwsa (sc4510007) had any water quality violations?

The EPA has 19 violations on file for Wcwsa (sc4510007), of which 17 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.