← New Mexico

Tap water quality report

Crescent Mhp (sc4360011)

EPA monitoring tested this supplier for 68 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

68
contaminants tested
12
detected
259
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Sumter

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
67
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 1998-01-01
TT Health-based Resolved 1998-01-01
TT Health-based Resolved 1997-01-01
TT Health-based Resolved 1997-01-01
MR Monitoring Resolved 2012-02-01
MR Monitoring Resolved 2012-02-01
MR Monitoring Resolved 2012-02-01
MR Monitoring Resolved 2012-02-01
Other Monitoring Resolved 2005-07-01
Other Monitoring Resolved 2005-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
8775 µg/L 88%
of the EPA limit 10000 µg/L
worst single sample: 9800 µg/L
116/116 SYR4 2012–2019
Combined Radium (-226 And -228)
1.88 pCi/L 38%
of the EPA limit 5 pCi/L
worst single sample: 2.72 pCi/L
16/28 SYR4 2012–2019
Lead
0.0029 mg/L 19%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Copper
284 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 300 µg/L
9/10 SYR4 2013–2019
Barium
83.9 µg/L 4.2%
of the EPA limit 2000 µg/L
worst single sample: 93 µg/L
8/12 SYR4 2013–2019
Cadmium
0.1400 µg/L 2.8%
of the EPA limit 5 µg/L
7/12 SYR4 2013–2019
Lead
10.08 µg/L 67%
of the EPA limit 15 µg/L
worst single sample: 11 µg/L
5/10 SYR4 2013–2019
Gross Beta Particle Activity
7.9425 pCi/L
No EPA limit set
worst single sample: 8.37 pCi/L
4/12 SYR4 2018–2019
Gross Alpha, Excl. Radon And U
3.78 pCi/L 25%
of the EPA limit 15 pCi/L
worst single sample: 3.9 pCi/L
3/19 SYR4 2012–2018
Nitrate-Nitrite
7450 µg/L 75%
of the EPA limit 10000 µg/L
worst single sample: 7600 µg/L
3/3 SYR4 2016
Combined Uranium
3.4 µg/L 11%
of the EPA limit 30 µg/L
1/4 SYR4 2012–2013
Fluoride
300 µg/L 7.5%
of the EPA limit 4000 µg/L
1/9 SYR4 2013–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CARIAS, MARYANN
Phone
401-480-9249
Email
[email protected]; [email protected]; [email protected]

Frequently asked questions about Crescent Mhp (sc4360011)

Is Crescent Mhp (sc4360011) tap water safe to drink?

EPA monitoring detected 12 contaminants in Crescent Mhp (sc4360011)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Crescent Mhp (sc4360011)'s water?

EPA monitoring detected Nitrate, Combined Radium (-226 And -228), Lead, Copper, Barium, and others. The full list with the level and data source for each is above.

How many people does Crescent Mhp (sc4360011) serve?

Crescent Mhp (sc4360011) reports serving 259 people in New Mexico, per its EPA record.

Has Crescent Mhp (sc4360011) had any water quality violations?

The EPA has 67 violations on file for Crescent Mhp (sc4360011), of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.