← South Carolina

Tap water quality report

Gilbert-Summit Wd (3220001)

EPA monitoring tested this supplier for 109 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
21
detected
10,400
people served
138
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Lexington

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

138
health-based violations
145
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2020-10-01 → 2020-12-31
MCL Health-based Archived 2020-07-01 → 2020-09-30
MCL Health-based Archived 2020-07-01 → 2020-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Combined Radium (-226 And -228)
7.8 pCi/L 156%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 9 pCi/L
115/139 SYR4 2012–2019
Nitrate
4600 µg/L 46%
of the EPA limit 10000 µg/L
worst single sample: 6000 µg/L
90/126 SYR4 2012–2019
Copper
918.05 µg/L 71%
of the EPA limit 1300 µg/L
worst single sample: 2360 µg/L
78/80 SYR4 2014–2019
Gross Alpha, Excl. Radon And U
9.615 pCi/L 64%
of the EPA limit 15 pCi/L
worst single sample: 32 pCi/L
58/109 SYR4 2012–2018
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
Lead
12.705 µg/L 85%
of the EPA limit 15 µg/L
worst single sample: 21 µg/L
22/80 SYR4 2014–2019
Gross Beta Particle Activity
9.292 pCi/L
No EPA limit set
worst single sample: 51.7 pCi/L
20/41 SYR4 2018–2019
Combined Uranium
11.7 µg/L 39%
of the EPA limit 30 µg/L
worst single sample: 13.5 µg/L
13/17 SYR4 2012–2016
Total Haloacetic Acids (HAA5)
3.575 µg/L 6%
of the EPA limit 60 µg/L
worst single sample: 4 µg/L
6/12 SYR4 2014–2019
Fluoride
1180 µg/L 30%
of the EPA limit 4000 µg/L
worst single sample: 1200 µg/L
5/17 SYR4 2014–2017
Dichloroacetic Acid
3.6985 µg/L
No EPA limit set
worst single sample: 4 µg/L
4/12 SYR4 2014–2019
Lithium
49.4 µg/L
No EPA limit set
4/16 UCMR-5 2024
Bromodichloromethane
2.70807 µg/L
No EPA limit set
worst single sample: 2.85 µg/L
3/12 SYR4 2014–2019
TTHM
10.43 µg/L 13%
of the EPA limit 80 µg/L
worst single sample: 10.84 µg/L
3/12 SYR4 2014–2019
Barium
154.95 µg/L 7.7%
of the EPA limit 2000 µg/L
worst single sample: 160 µg/L
2/18 SYR4 2014–2017
Chloroform
4.25836 µg/L
No EPA limit set
worst single sample: 4.42 µg/L
2/12 SYR4 2014–2019
Dibromochloromethane
3.8175 µg/L
No EPA limit set
worst single sample: 3.89 µg/L
2/12 SYR4 2014–2019
Nitrate-Nitrite
2690 µg/L 27%
of the EPA limit 10000 µg/L
worst single sample: 2700 µg/L
2/3 SYR4 2014–2016
Bromoform
2.86 µg/L
No EPA limit set
1/12 SYR4 2014–2019
Dibromoacetic Acid
2.3 µg/L
No EPA limit set
1/12 SYR4 2014–2019
Trichloroacetic Acid
1 µg/L
No EPA limit set
1/12 SYR4 2014–2019
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GASSARO, MARTIN
Phone
803-892-5544
Email
[email protected]; [email protected]

Frequently asked questions about Gilbert-Summit Wd (3220001)

Is Gilbert-Summit Wd (3220001) tap water safe to drink?

EPA monitoring detected 21 contaminants in Gilbert-Summit Wd (3220001)'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gilbert-Summit Wd (3220001)'s water?

EPA monitoring detected Combined Radium (-226 And -228), Nitrate, Copper, Gross Alpha, Excl. Radon And U, Lead, and others. The full list with the level and data source for each is above.

How many people does Gilbert-Summit Wd (3220001) serve?

Gilbert-Summit Wd (3220001) reports serving 10,400 people in South Carolina, per its EPA record.

Has Gilbert-Summit Wd (3220001) had any water quality violations?

The EPA has 145 violations on file for Gilbert-Summit Wd (3220001), of which 138 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.