Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Resolved | 2024-10-01 → 2024-12-31 |
| TT | Health-based | Resolved | 2014-10-01 → 2014-12-31 |
| TT | Health-based | Resolved | 2014-10-01 → 2014-12-31 |
| TT | Health-based | Resolved | 2014-10-01 → 2014-12-31 |
| TT | Health-based | Resolved | 2014-10-01 → 2014-12-31 |
| TT | Health-based | Resolved | 2014-07-01 → 2014-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Dibromochloromethane | 20.8 µg/L No EPA limit set
worst single sample: 27.4 µg/L | 265/268 | SYR4 | 2012–2019 |
| Bromodichloromethane | 28.89 µg/L No EPA limit set
worst single sample: 34 µg/L | 252/252 | SYR4 | 2012–2019 |
| Chloroform | 67.19 µg/L No EPA limit set
worst single sample: 91.4 µg/L | 252/252 | SYR4 | 2012–2019 |
| TTHM | 94.09 µg/L 118% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 118 µg/L | 252/252 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 42 µg/L 70% of the EPA limit 60 µg/L
worst single sample: 59 µg/L | 216/252 | SYR4 | 2012–2019 |
| Copper | 150.4 µg/L 12% of the EPA limit 1300 µg/L
worst single sample: 326 µg/L | 149/157 | SYR4 | 2013–2019 |
| Lead | 27.2 µg/L 181% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 48 µg/L | 86/157 | SYR4 | 2013–2019 |
| Bromoform | 7.8215 µg/L No EPA limit set
worst single sample: 10.1 µg/L | 80/252 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 13.7 µg/L No EPA limit set
worst single sample: 18.2 µg/L | 40/40 | SYR4 | 2018–2019 |
| Trichloroacetic Acid | 14.2 µg/L No EPA limit set
worst single sample: 16.4 µg/L | 39/40 | SYR4 | 2018–2019 |
| Nitrate | 750 µg/L 7.5% of the EPA limit 10000 µg/L | 18/20 | SYR4 | 2012–2019 |
| Lead | 0.0098 mg/L 65% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Fluoride | 889.2 µg/L 22% of the EPA limit 4000 µg/L
worst single sample: 902 µg/L | 9/9 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 10.748 µg/L No EPA limit set
worst single sample: 11.2 µg/L | 5/40 | SYR4 | 2018–2019 |
| Barium | 40.8 µg/L 2% of the EPA limit 2000 µg/L
worst single sample: 42 µg/L | 4/8 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.19 µg/L No EPA limit set | 1/40 | SYR4 | 2018–2019 |
| Mercury | 0.3000 µg/L 15% of the EPA limit 2 µg/L | 1/9 | SYR4 | 2012–2019 |
| Nitrite | 120 µg/L 12% of the EPA limit 1000 µg/L | 1/10 | SYR4 | 2012–2019 |
90 contaminants tested, none detected
Utility contact
Frequently asked questions about Wilkinsburg-Penn Jt Water Auth
Is Wilkinsburg-Penn Jt Water Auth tap water safe to drink?
EPA monitoring detected 18 contaminants in Wilkinsburg-Penn Jt Water Auth's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Wilkinsburg-Penn Jt Water Auth's water?
EPA monitoring detected Dibromochloromethane, Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Wilkinsburg-Penn Jt Water Auth serve?
Wilkinsburg-Penn Jt Water Auth reports serving 125,000 people in Pennsylvania, per its EPA record.
Has Wilkinsburg-Penn Jt Water Auth had any water quality violations?
The EPA has 161 violations on file for Wilkinsburg-Penn Jt Water Auth, of which 29 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.