Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-04-01 → 2025-06-30 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate-Nitrite | 10050 µg/L 100% of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 11200 µg/L | 116/116 | SYR4 | 2012–2019 |
| TTHM | 127.42 µg/L 159% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 219.2 µg/L | 45/47 | SYR4 | 2012–2019 |
| Dibromochloromethane | 46.16 µg/L No EPA limit set
worst single sample: 107 µg/L | 43/47 | SYR4 | 2012–2019 |
| Bromoform | 65.805 µg/L No EPA limit set
worst single sample: 84.4 µg/L | 42/47 | SYR4 | 2012–2019 |
| Bromodichloromethane | 18.65 µg/L No EPA limit set
worst single sample: 28.1 µg/L | 31/47 | SYR4 | 2012–2019 |
| Copper | 104 µg/L 8% of the EPA limit 1300 µg/L
worst single sample: 155 µg/L | 28/30 | SYR4 | 2012–2018 |
| Chloroform | 10.44 µg/L No EPA limit set
worst single sample: 14.6 µg/L | 27/47 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 21.02 µg/L No EPA limit set
worst single sample: 23.9 µg/L | 25/49 | SYR4 | 2012–2019 |
| Lead | 14.9 µg/L 99% of the EPA limit 15 µg/L
worst single sample: 23.5 µg/L | 21/29 | SYR4 | 2012–2018 |
| Total Haloacetic Acids (HAA5) | 28.3 µg/L 47% of the EPA limit 60 µg/L
worst single sample: 33.6 µg/L | 21/47 | SYR4 | 2012–2019 |
| Lead | 0.0076 mg/L 51% of the EPA limit 0.0150 mg/L | 12/12 | LCR | 2024 |
| Dichloroacetic Acid | 7.878 µg/L No EPA limit set
worst single sample: 8.4 µg/L | 10/48 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.7 µg/L No EPA limit set
worst single sample: 2.8 µg/L | 5/48 | SYR4 | 2012–2019 |
| Combined Uranium | 3.2085 µg/L 11% of the EPA limit 30 µg/L
worst single sample: 3.27 µg/L | 4/5 | SYR4 | 2012–2019 |
| Gross Alpha, Excl. Radon And U | 10.7615 pCi/L 72% of the EPA limit 15 pCi/L
worst single sample: 12.2 pCi/L | 4/5 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 8.3165 pCi/L No EPA limit set
worst single sample: 8.69 pCi/L | 4/5 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 1.29 µg/L No EPA limit set
worst single sample: 1.3 µg/L | 3/47 | SYR4 | 2012–2019 |
| Arsenic | 1.08481 µg/L 11% of the EPA limit 10 µg/L
worst single sample: 1.0871 µg/L | 2/4 | SYR4 | 2013–2019 |
| Barium | 201.9 µg/L 10% of the EPA limit 2000 µg/L
worst single sample: 202 µg/L | 2/2 | SYR4 | 2017 |
| Combined Radium (-226 And -228) | 1.4072 pCi/L 28% of the EPA limit 5 pCi/L
worst single sample: 1.445 pCi/L | 2/5 | SYR4 | 2012–2019 |
| Fluoride | 0.2500 µg/L 0% of the EPA limit 4000 µg/L | 2/2 | SYR4 | 2017 |
| Monochloroacetic Acid | 2.6 µg/L No EPA limit set | 1/48 | SYR4 | 2012–2019 |
57 contaminants tested, none detected
Utility contact
Frequently asked questions about Tillman Co Rwd #1
Is Tillman Co Rwd #1 tap water safe to drink?
EPA monitoring detected 22 contaminants in Tillman Co Rwd #1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Tillman Co Rwd #1's water?
EPA monitoring detected Nitrate-Nitrite, TTHM, Dibromochloromethane, Bromoform, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Tillman Co Rwd #1 serve?
Tillman Co Rwd #1 reports serving 1,500 people in Oklahoma, per its EPA record.
Has Tillman Co Rwd #1 had any water quality violations?
The EPA has 246 violations on file for Tillman Co Rwd #1, of which 153 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.