Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| MCL | Health-based | Resolved | 2002-01-01 → 2002-01-31 |
| MCL | Health-based | Resolved | 2002-01-01 → 2002-01-31 |
| MCL | Health-based | Resolved | 2002-01-01 → 2002-01-31 |
| MCL | Health-based | Resolved | 2002-01-01 → 2002-01-31 |
| MCL | Health-based | Resolved | 1998-08-01 → 1998-08-31 |
| Other | Monitoring | Resolved | 2025-07-01 |
| RPT | Monitoring | Resolved | 2024-10-17 |
| RPT | Monitoring | Resolved | 2024-10-17 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 299.6 µg/L 23% of the EPA limit 1300 µg/L
worst single sample: 645 µg/L | 123/123 | SYR4 | 2012–2019 |
| Lead | 9.6325 µg/L 64% of the EPA limit 15 µg/L
worst single sample: 17 µg/L | 84/123 | SYR4 | 2012–2019 |
| Lead | 0.0017 mg/L 12% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2025 |
| TTHM | 9.76 µg/L 12% of the EPA limit 80 µg/L
worst single sample: 11.6 µg/L | 17/39 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 1340 µg/L 13% of the EPA limit 10000 µg/L | 16/16 | SYR4 | 2012–2019 |
| Chloroform | 3.759 µg/L No EPA limit set
worst single sample: 4.27 µg/L | 15/27 | SYR4 | 2012–2019 |
| Bromodichloromethane | 3.754 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 14/27 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.825 µg/L No EPA limit set
worst single sample: 3.02 µg/L | 14/27 | SYR4 | 2012–2019 |
| Bromoform | 0.9460 µg/L No EPA limit set
worst single sample: 0.9600 µg/L | 3/27 | SYR4 | 2012–2019 |
| Arsenic | 0.6884 µg/L 6.9% of the EPA limit 10 µg/L
worst single sample: 0.6930 µg/L | 2/4 | SYR4 | 2012–2017 |
| Combined Radium (-226 And -228) | 1.45825 pCi/L 29% of the EPA limit 5 pCi/L
worst single sample: 1.475 pCi/L | 2/2 | SYR4 | 2012–2017 |
| Gross Alpha, Excl. Radon And U | 4.483 pCi/L 30% of the EPA limit 15 pCi/L
worst single sample: 4.5 pCi/L | 2/2 | SYR4 | 2012–2017 |
| Antimony, Total | 1.26 µg/L 21% of the EPA limit 6 µg/L | 1/1 | SYR4 | 2015 |
| Barium | 49 µg/L 2.5% of the EPA limit 2000 µg/L | 1/1 | SYR4 | 2015 |
| Di(2-ethylhexyl) Phthalate | 2.6 µg/L 43% of the EPA limit 6 µg/L | 1/6 | SYR4 | 2018–2019 |
| Fluoride | 840 µg/L 21% of the EPA limit 4000 µg/L | 1/1 | SYR4 | 2015 |
| Gross Beta Particle Activity | 3.89 pCi/L No EPA limit set | 1/2 | SYR4 | 2012–2017 |
| Total Haloacetic Acids (HAA5) | 1.11 µg/L 1.9% of the EPA limit 60 µg/L | 1/39 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 1.11 µg/L No EPA limit set | 1/27 | SYR4 | 2012–2019 |
90 contaminants tested, none detected
Utility contact
Frequently asked questions about Ada
Is Ada tap water safe to drink?
EPA monitoring detected 19 contaminants in Ada's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Ada's water?
EPA monitoring detected Copper, Lead, Lead, TTHM, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.
How many people does Ada serve?
Ada reports serving 22,600 people in Oklahoma, per its EPA record.
Has Ada had any water quality violations?
The EPA has 27 violations on file for Ada, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.